12 Incomplete description of repeatNumber Closed Normal Change Request 2021-02-15 16:31:31
 
Change Request Incomplete description of repeatNumber
Id chdachpharm-issue-12
Status Closed
Priority Normal
Last Tracking 2021-02-15 16:31:31  by  Quentin Ligier
    
Concerns
Template
false
Dosage Instructions Start/Stop, Frequency, Dose (chdachpharm-template-entry-35)
/
/
Template 2.16.756.5.30.1.1.10.4.35 (2019-08-27 16:30:05) Dosage Instructions Start/Stop, Frequency, Dose
Status Draft
/
-
/
-
Events
Tracking Closed 2021-02-15 16:31:31 : Tracking by Quentin Ligier
Description
Tracking Open 2021-01-21 12:04:02 : Tracking by Quentin Ligier
Edited by Quentin Ligier ( 2021-01-21 14:51:46 )
Description
Finding:

As per IHE PCC TF-2 §6.3.4.18.7 and IHE PHARM PRE §6.3.4.2.3.9, the repeatNumber is constrained to have either the attribute value or the attribute nullFlavor='NI'.

Suggestion:

This template could be improved by including these constraints. I'm not sure if it's possible, but for the sake of completeness, the value could also be constrained to ≥ 0.
The schematron would be more precise while validating this part.
If that seems right, I'll also propose a patch for the XML Schema that is expecting an IVL_INT here.

Further explanation:

-

    
Labels
Preview Code HTML color Display Name Description