This form has to be reloaded. This most likely happened because your session has expired, which might take to the login page. (If you think that you shouldn't see this message and that the problem persists, please contact support.)
- Template uses a different code, thereby violates IHE template specification.
- I propose to revert "our" spec to the original template that you quoted. This implies REMOVING the required author, and REVERTING to the LOINC code 882-1 which is more appropriate than the current replacement 34530-6 (which actually signifies an observation panel, while our SNOMED answer list contains the pre-coordinated codes, and not two separate observations!)
- see Blood Group Observation is here: https://art-decor.ihe-europe.net/art-decor/decor-templates--IHE-PCC-?section=templates&id=1.3.6.1.4.1.19376.1.5.3.1.4.13.6&effectiveDate=2017-03-23T10:17:49
- last template ID is empty.
- change to origina spec. 2.16.840.1.113883.10.20.1.31
-
- when trying to edit the template, an error is returned:"A submission error occurred: resource-error ; Status: 400 ; URI: http://localhost:8877/art/modules/get-decor-template-for-edit.xquery?prefix=epsos-&id=1.3.6.1.4.1.19376.1.5.3.1.4.13.6&effectiveDate=2017-07-12T16:25:39&mode=edit&language=en-US ; Headers: DateTue, 18 Jul 2017 19:52:59 GMT Content-Typeapplication/xml; charset=UTF-8 Transfer-Encodingchunked ServerJetty(8.1.9.v20130131) ; Body:
"
- text cardinality is 1...*
- The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]
- effectiveTime is 1..*
-The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]