Template

Show index

Template BC Laboratory Battery Organizer 2016‑04‑05 01:44:00

Id1.3.6.1.4.1.19376.1.3.1.4Effective Date2016‑04‑05 01:44:00
Statusdraft DraftVersion Label
NameBCLaboratoryBatteryOrganizerDisplay NameBC Laboratory Battery Organizer
Description
A Laboratory Battery Organizer is used to group Laboratory Observations for a battery of tests. Laboratory Battery Organizer, when present, SHALL be recorded as an <organizer> in an <entryRelationship> under the Laboratory Data Processing Entry as demonstrated in the figure below. The figure below shows how the information for this element is coded, and further constraints are provided in the following sections.

See also IHE PCC Wiki Content
ContextParent nodes of template element with id 1.3.6.1.4.1.19376.1.3.1.4
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 2 transactions and 26 templates, Uses 2 templates
Used by as NameVersion
2.16.840.1.113883.2.4.3.11.60.7.4.2.13.1Transactiondeprecated Registration (4.0)2017‑09‑04
2.16.840.1.113883.2.4.3.11.60.7.4.2.13.1Transactionfinal Registration (4.1)2017‑12‑31
1.2.40.0.34.11.30020Containmentretired ELGA Spezimen-Act-Entry Allgemein2012‑01‑07
1.2.40.0.34.11.30020Containmentretired ELGA Spezimen-Act-Entry Allgemein2014‑03‑04
1.2.40.0.34.11.30020Containmentretired ELGA Spezimen-Act-Entry Allgemein2015‑04‑30
1.2.40.0.34.11.30020Containmentretired ELGA Spezimen-Act-Entry Allgemein2017‑02‑20
1.2.40.0.34.11.30020Containmentdraft ELGA Spezimen-Act-Entry Allgemein2017‑02‑22
1.2.40.0.34.11.30026Containmentretired Antibiogram (Laboratory Isolate Organzier)2012‑07‑07
1.2.40.0.34.11.30026Containmentactive Antibiogram (Laboratory Isolate Organzier)2014‑04‑15
1.3.6.1.4.1.19376.1.3.1Containmentactive Laboratory Report Data Processing Entry (2017)2008‑08‑08
1.3.6.1.4.1.19376.1.3.1Containmentdraft BC Laboratory Report Data Processing Entry2016‑04‑05 01:31:43
1.3.6.1.4.1.19376.1.3.1.5Containmentactive Laboratory Isolate Organizer (2017)2008‑08‑08
1.3.6.1.4.1.19376.1.3.1.5Containmentdraft BC Laboratory Isolate Organizer2016‑09‑29 14:55:37
2.16.840.1.113883.2.4.3.11.60.7.10.1linkretired Laboratory Battery or Isolate2017‑10‑16 14:59:25
2.16.840.1.113883.2.4.3.11.60.7.10.1linkpending Laboratory Battery or Isolate2021‑08‑30
2.16.840.1.113883.2.4.3.11.60.7.10.4Containmentretired Laboratory Isolate Organizer (Specimen)2017‑10‑16
2.16.840.1.113883.2.4.3.11.60.7.10.4Containmentpending Laboratory Isolate Organizer (Specimen)2021‑08‑30 14:45:51
2.16.840.1.113883.2.4.3.11.60.7.10.4Containmentcancelled Laboratory Isolate Organizer (Specimen)2021‑10‑27 17:00:31
2.16.840.1.113883.2.4.3.11.60.25.10.51linkdraft Lab2Zorg - Sharing Laboratory Reports (XD-LAB) (2017)2018‑06‑05 14:37:04
2.16.840.1.113883.2.4.3.11.60.25.10.52linkcancelled Laboratory Specialty Section (2017)2018‑06‑05 14:38:48
2.16.840.1.113883.2.4.3.11.60.25.10.52linkactive Laboratory Specialty Section2021‑10‑27
2.16.840.1.113883.2.4.3.11.60.25.10.52linkdraft Laboratory Specialty Section2022‑12‑20 14:13:14
2.16.840.1.113883.2.4.3.11.60.25.10.53linkretired Laboratory Report Data Processing Entry (2017)2018‑06‑05 14:42:09
2.16.840.1.113883.2.4.3.11.60.25.10.53linkpending Laboratory Report Data Processing Entry (2017)2021‑10‑27
2.16.840.1.113883.2.4.3.11.60.25.10.54linkcancelled Laboratory Report Item Section (2017)2018‑06‑05 14:44:20
2.16.840.1.113883.2.4.3.11.60.25.10.54linkactive Laboratory Report Item Section (2017)2021‑10‑27
2.16.840.1.113883.3.1937.99.61.41.10.17Containmentdraft Antibiogram (Laboratory Isolate Organzier)-Sandbox-sm2019‑03‑26 18:03:30
2.16.840.1.113883.3.1937.99.61.41.10.27Containmentdraft Laboratory Report Data Processing Entry_Sandbox-sm (2017)2019‑03‑27 16:09:06
Uses as NameVersion
1.3.6.1.4.1.19376.1.3.1.6Containmentdraft BC Laboratory ObservationDYNAMIC
1.3.6.1.4.1.19376.1.5.3.1.4.2Containmentactive IHE Comment Entry (2014)DYNAMIC
RelationshipSpecialization: template 2.16.840.1.113883.10.12.305 CDA Organizer (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.4 Laboratory Battery Organizer (2008‑08‑08)
ref
XDLAB-
Example
Example
<organizer classCode="BATTERY" moodCode="EVN">
  <templateId root="1.3.6.1.4.1.19376.1.3.1.4"/>  <id root=" " extension=" "/>  <code code="29576-6" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Microbiology Susceptibility">
    <originalText>
      <reference value="susceptibilityTest"/>    </originalText>
  </code>
  <statusCode code="completed"/>  <effectiveTime value="20071108000000.0000-0500"/>  <specimen typeCode="SPC">
    <specimenRole classCode="SPEC">
      <!-- ... -->
    </specimenRole>
  </specimen>
  <performer typeCode="PRF">
    <templateId root="1.3.6.1.4.1.19376.1.3.3.1.7"/>    <!-- ... -->
  </performer>
  <author typeCode="AUT">
    <templateId root=" "/>    <!-- ... -->
  </author>
  <participant typeCode="AUTHEN">
    <templateId root="1.3.6.1.4.1.19376.1.3.3.1.5"/>    <!-- ... -->
  </participant>
  <participant typeCode="RESP">
    <!-- ... -->
  </participant>
  <participant typeCode="DEV">
    <!-- ... -->
  </participant>
  <component>
    <observation classCode="OBS" moodCode="EVN">
      <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/>      <!-- ... -->
    </observation>
  </component>
  <component>
    <observation classCode="OBS" moodCode="EVN">
      <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/>      <!-- ... -->
    </observation>
  </component>
  <component>
    <act classCode="ACT" moodCode="EVN">
      <templateId extension="1.3.6.1.4.1.19376.1.5.3.1.4.2"/>      <code code="48767-8" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Annotation Comment"/>      <text>
        <reference value="organizerComment"/>      </text>
      <statusCode code="completed"/>    </act>
  </component>
</organizer>
ItemDTCardConfDescriptionLabel
hl7:organizer
1 … *MBCLadotsizer
hl7:templateId
II1 … 1MBCLadotsizer
@root
uid1 … 1F1.3.6.1.4.1.19376.1.3.1.4
hl7:id
II0 … *RThe organizer identifier MAY be present.BCLadotsizer
hl7:code
CE0 … 1The unique battery test code from an international standard, such as LOINC, MAY be present. This is different from [1.3.6.1.4.1.19376.1.3.1.6|Laboratory Observation], where it is required.BCLadotsizer
hl7:statusCode
CS1 … 1MThe test status SHALL be either "completed", "aborted", or "obsolete". A status of completed means the all expected results are present. A status of aborted means at least one or more of the tests could not be performed and has no result, some results may be present. A status of obsolete means the battery has been replaced by a newer battery (following it) in this revision of the report.BCLadotsizer
 CONF
@code shall be "completed"
or
@code shall be "aborted"
or
@code shall be "obsolete"
hl7:effectiveTime
TS0 … 1The battery's relevant clinical time (ideally specimen collection time) MAY be present.BCLadotsizer
hl7:specimen
0 … 1A Laboratory Battery Organizer MAY contain the <specimen>, typeCode="SPC" when it is different from the one documented at a higher level, including the header.BCLadotsizer
hl7:performer
0 … 1A Laboratory Battery Organizer MAY contain the person who performed the entire battery when it is different from the one documented at a higher level, including the header.BCLadotsizer
hl7:author
0 … *A Laboratory Battery Organizer SHALL contain author(s) of the Laboratory Battery when multiple header author(s) exist and not all apply to this Laboratory Battery. The author/time element carries the date&time the laboratory report was produced by the system.BCLadotsizer
hl7:participant
0 … 1A Laboratory Battery Organizer MAY contain up to 3 types of participants "AUTHEN", "RESP", and "DEV".
  • AUTHEN: The verifier of the battery organizer. In the case where a laboratory report has multiple verifiers. Each verifier is attached to the subset of batteries/observations he or she verified, by the means of a <participant> element.
  • RESP: The person responsible for the provision of the battery. In the case where this battery is subcontracted to an external laboratory, this external laboratory (with its address and telcom) and the actual performer is represented by a <performer> element, whereas the Director of this subcontractor laboratory is carried by the <participant> element being attached to the same level as the <performer> element.
  • DEV: A device or equipment, which was used to produce this battery of results (e.g. an analyzer).
BCLadotsizer
hl7:component
1 … *MThe Laboratory Observations performed in the battery. A Laboratory Battery Organizer SHALL have at least one Laboratory Observation.
Contains 1.3.6.1.4.1.19376.1.3.1.6 BC Laboratory Observation (DYNAMIC)
BCLadotsizer
@typeCode
cs0 … 1FCOMP
hl7:component
0 … 1RThe Battery Organizer comment using the Annotation Comment template.
Contains 1.3.6.1.4.1.19376.1.5.3.1.4.2 IHE Comment Entry (DYNAMIC)
BCLadotsizer
@typeCode
cs1 … 1FCOMP