Item | DT | Card | Conf | Description | Label |
---|
hl7:observation
| | 1 … 1 | M | | XeHLtion |
@classCode
| cs | 1 … 1 | F | OBS |
@moodCode
| cs | 1 … 1 | F | EVN |
hl7:templateId
| II | 1 … 1 | M | | XeHLtion |
@root
| uid | 1 … 1 | F | 2.16.840.1.113883.2.51.10.56 |
hl7:id
| II | 0 … 1 | | A Laboratory Observation identifier MAY be present. | XeHLtion |
hl7:code
| CD (preferred) | 1 … 1 | R | Unique test code in an international standard (LOINC or SNOMED CT) or a national standard (e.g. JC10 in Japan)
| XeHLtion |
| CONF | |
hl7:qualifier
| CR | 0 … 1 | | Accreditation status
Accreditation status holds information about status of the test, i.e., whether laboratory has been accredited for provisioning of the test or not. If this element is not given, the laboratory was accredited (default). | XeHLtion |
hl7:value
| CD (preferred) | 1 … 1 | M | | XeHLtion |
| CONF | |
hl7:translation
| CD | 0 … 1 | | Local test code (e.g. internally used by the performing laboratory) | XeHLtion |
hl7:statusCode
| CS (required) | 1 … 1 | M | Formal status of that observation according to IHE XD-LAB profile: set to ‘completed’ when the result is present
set to ‘aborted’ if the test could not be performed
Note: it is merely the information, whether or not the value is present or not. It is the status seen from the layer of the document instance. It doesn NOT consider this value (or this document) being part of a process chain or workflow.
| XeHLtion |
| CONF | @code shall be "completed" | or | @code shall be "aborted" |
|
xeh:observationStatus
| CE.IPS (required) | 1 … 1 | M | Status of Laboratory Test in the context of the workflow / business process, such as preliminary, final, corrected, ...
The value must not contradict the value set in hl7:statusCode
Note: this is the more comprehensive status of that observation on the layer of workflow and process. | XeHLtion |
| CONF | |
hl7:effectiveTime
| IVL_TS | 0 … 1 | R | Physiologically relevant time | XeHLtion |
Choice | 1 … 1 | | Elements to choose from:- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
- hl7:value
|
hl7:value
| CE.IPS | 0 … 1 | R | Coded results | XeHLtion |
hl7:value
| ED | 0 … 1 | R | Textual results: Text in the narrative text element should be referenced here Media Results: Media (pictures, ...) can be embedded here in B64 encoding | XeHLtion |
hl7:value
| INT | 0 … 1 | R | Integer numeric results
| XeHLtion |
hl7:value
| IVL_INT | 0 … 1 | R | Integer numeric interval results | XeHLtion |
hl7:value
| PQ | 0 … 1 | R | Physical quantity results (value and unit) | XeHLtion |
hl7:value
| IVL_PQ | 0 … 1 | R | Physical quantity interval results (value and unit) | XeHLtion |
hl7:value
| REAL | 0 … 1 | R | Real numeric results | XeHLtion |
hl7:value
| IVL_REAL | 0 … 1 | R | Real numeric interval results | XeHLtion |
hl7:value
| RTO_QTY_QTY | 0 … 1 | R | Ratio result (integer numeric, real numeric, physical quantity) | XeHLtion |
hl7:value
| TS | 0 … 1 | R | Timestamp results | XeHLtion |
hl7:value
| BL | 0 … 1 | R | Boolean results (true / false) | XeHLtion |
xeh:measurementUncertainty
| PQ | 0 … 1 | | Measurement uncertainty in percent
Example: <xeh:measurementUncertainty value="2" unit="%"/> | XeHLtion |
xeh:testCalibrator
| CE.IPS | 0 … 1 | | Test calibrators, either as "coded entry" or "narrative text" (direct or reference)
Examples:
<xeh:testCalibrator code="" codeSystem=""/>
-- or --
<xeh:testCalibrator> <originalText>IS 93/76</originalText> </xeh:testCalibrator>
-- or --
<xeh:testCalibrator> <originalText><reference value="#ID_of_text_in_narrative"/></originalText> </xeh:testCalibrator>
| XeHLtion |
hl7:interpretationCode
| CE.IPS | 0 … 1 | R | Result interpretation is usually documented within the referenceRange element to which it belongs.
If no referenceRange is present, this element SHALL be used for result interpretation, IF KNOWN.
If a referenceRange is present, this element SHALL NOT be used.
| XeHLtion |
hl7:methodCode
| CE.IPS | 0 … 1 | R | ExaminationTechnique (method) used for this observation expressed with ObservationMethod vocabulary (CWE) | XeHLtion |
Choice | 0 … 1 | | Elements to choose from: |
hl7:subject
| | | NP | subject in case of a non-human subject Contains 1.3.6.1.4.1.19376.1.3.3.1.2.1 Non-Human Subject (DYNAMIC) | XeHLtion |
@typeCode
| cs | 0 … 1 | F | SBJ |
hl7:subject
| | 0 … 1 | | subject in case of a non-human subject Contains 1.3.6.1.4.1.19376.1.3.3.1.3.1 Human Patient with Non-Human Subject (DYNAMIC) | XeHLtion |
@typeCode
| cs | 0 … 1 | F | SBJ |
hl7:performer
| | 0 … * | | performer participation. Performer to supersede those recorded at higher level. Contains 1.3.6.1.4.1.19376.1.3.3.1.7 Laboratory Performer (DYNAMIC) | XeHLtion |
hl7:author
| | 0 … * | R | author participation used to supersede the authors of higher level. Contains 1.3.6.1.4.1.19376.1.3.10.9.17 Author with Name, Addr, Telecom (DYNAMIC) | XeHLtion |
hl7:participant
| | 0 … 1 | | AUTHEN: The verifier of the battery organizer. In the case where a laboratory report has multiple verifiers. Each verifier is attached to the subset of batteries/observations he or she verified, by the means of a <participant> element.
Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile | XeHLtion |
where [@typeCode='AUTHEN'] | |
@typeCode
| cs | 1 … 1 | F | AUTHEN |
Included | 1 … 1 | M | from 2.16.840.1.113883.2.51.10.74 XeH Lab Results Validator Participant (DYNAMIC) |
hl7:time
| TS | 1 … 1 | M | | XeHLpant |
hl7:participantRole
| | 1 … 1 | M | | XeHLpant |
@classCode
| cs | 0 … 1 | F | ROL |
hl7:id
| II | 1 … * | R | | XeHLpant |
hl7:code
| CE.IPS (preferred) | 0 … 1 | | A code, which identifies the profession/competence/specialty of the author when it is a person.
| XeHLpant |
| CONF | |
hl7:addr
| AD | 0 … * | | | XeHLpant |
hl7:telecom
| TEL | 0 … * | | | XeHLpant |
hl7:playingEntity
| | 0 … 1 | R | | XeHLpant |
hl7:name
| PN | 1 … 1 | R | | XeHLpant |
hl7:participant
| | 0 … 1 | | RESP: The person responsible for the provision of the battery. In the case where this battery is subcontracted to an external laboratory, this external laboratory (with its address and telcom) and the actual performer is represented by a <performer> element, whereas the Director of this subcontractor laboratory is carried by the <participant> element being attached to the same level as the <performer> element. Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
| XeHLtion |
where [@typeCode='RESP'] | |
@typeCode
| cs | 1 … 1 | F | RESP |
hl7:participant
| | 0 … 1 | | DEV: A device or equipment, which was used to produce this battery of results (e.g. an analyzer).
Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
| XeHLtion |
where [@typeCode='DEV'] | |
@typeCode
| cs | 1 … 1 | F | DEV |
Included | 1 … 1 | M | from 2.16.840.1.113883.2.51.10.91 XeH Lab Device Participant (DYNAMIC) |
hl7:participantRole
| | 1 … 1 | M | | XeHLpant |
hl7:id
| II | 0 … * | | The UDI Device Identifier MAY be specified as a second id element.
| XeHLpant |
hl7:playingDevice
| | 1 … 1 | M | | XeHLpant |
hl7:code
| CE.IPS | 0 … 1 | | Coded product type
| XeHLpant |
hl7:manufacturerModelName
| SC | 0 … 1 | | The element manufacturerModelName“ is intended to be used in the same manner as element “modelNumber” specified in the FHIR device resource. It shall carry model information of the device or software provided in element softwareName
| XeHLpant |
hl7:softwareName
| SC | 1 … 1 | M | The element softwareName is the primary element and intended to be used in the same manner as element “deviceName” specified in the FHIR device resource. It should carry the name of the device or software.
Is SHOULD including the manufacturer name.
Note: In case of usage for laboratory related documentation (e.g. Laboratory Result Report), the device structure is also used to record "Laboratory Kits" used for the examination.
| XeHLpant |
hl7:entryRelationship
| | 0 … * | R | Comment on this Observation Contains 1.3.6.1.4.1.19376.1.5.3.1.4.2 IHE Comment Entry (DYNAMIC) | XeHLtion |
hl7:entryRelationship
| | 0 … * | R | Specimen Collection Contains 2.16.840.1.113883.2.51.10.42 XeH Specimen Collection (DYNAMIC) | XeHLtion |
hl7:entryRelationship
| | 0 … * | R | Previous observations obtained for the same patient, test, same method, same unit (1) | XeHLtion |
where [@typeCode='REFR'] | |
@typeCode
| cs | 1 … 1 | F | REFR |
hl7:observation
| | 1 … 1 | R | | XeHLtion |
@classCode
| cs | 1 … 1 | F | OBS |
@moodCode
| cs | 1 … 1 | F | EVN |
hl7:code
| | 1 … 1 | R | | XeHLtion |
hl7:statusCode
| | 1 … 1 | R | | XeHLtion |
@code
| | 1 … 1 | F | completed |
hl7:effectiveTime
| | 1 … 1 | R | | XeHLtion |
hl7:value
| | 1 … 1 | R | | XeHLtion |
hl7:entryRelationship
| | 0 … 1 | | Internal reference to an "Order Id" provided in the header of the document (inFullfilmentOf/order/id).
Superseeds present references in overarching containers of this observation (e.g. battery)
Note: Usually used in case of multiple orders present
Contains 2.16.840.1.113883.2.51.10.18 XeH Internal Reference (DYNAMIC) | XeHLtion |
hl7:entryRelationship
| | 0 … 1 | | Internal reference to an "Ordering provider" provided in the header of the document (participant[@typeCode='REF']/associatedEntity/id).
Superseeds present references in overarching containers of this observation (e.g. battery)
Note: Usually used in case of multiple orders present
Contains 2.16.840.1.113883.2.51.10.18 XeH Internal Reference (DYNAMIC) | XeHLtion |
hl7:entryRelationship
| | 0 … 1 | | Local Test Result Value Contains 2.16.840.1.113883.2.51.10.93 XeH Laboratory Observation (local value) (DYNAMIC) | XeHLtion |
hl7:referenceRange
| | 0 … * | R | One to many Reference ranges for the current test result
| XeHLtion |
@typeCode
| cs | 0 … 1 | F | REFV |
hl7:observationRange
| | 1 … 1 | M | | XeHLtion |
@classCode
| cs | 0 … 1 | F | OBS |
@moodCode
| cs | 0 … 1 | F | EVN.CRT |
hl7:code
| CD (preferred) | 0 … 1 | | Result Interpretation Type
Type of the result interpretation indicates what part of the targeted reference population it applies to. For example, interpretation using normal or therapeutic range. Default is "normal" interpretation type. | XeHLtion |
| CONF | |
Choice | 1 … 1 | | Reference range as interval Elements to choose from:- hl7:value
- hl7:value
- hl7:value
|
hl7:value
| IVL_INT | 0 … 1 | R | Integer numeric interval results | XeHLtion |
hl7:value
| IVL_PQ | 0 … 1 | R | Physical quantity interval results (value and unit) | XeHLtion |
hl7:value
| IVL_REAL | 0 … 1 | R | Real numeric interval results | XeHLtion |
hl7:interpretationCode
| CE (preferred) | 1 … 1 | R | Result Interpretation Code
One or more codes interpreting the result, expressed with ObservationInterpretation vocabulary (e.g. H = high, L = low)
In case of a antimicrobial susceptibility test in microbiology, the vocabulary domain is ObservationInterpretationSusceptibility: S = susceptible, R = resistant, I = intermediate, VS = very susceptible, MS = moderately susceptible
| XeHLtion |
| CONF | |
lab:precondition
| | 0 … * | | Extension to CDA Clinical statement | XeHLtion |
@typeCode
| cs | 1 … 1 | F | PRCN |
lab:criterion
| | 1 … 1 | R | | XeHLtion |
@classCode
| cs | 1 … 1 | F | COND |
@moodCode
| cs | 1 … 1 | F | EVN |
lab:code
| CE | 1 … 1 | R | Code of the criterion (e.g. age, sex) | XeHLtion |
lab:value
| | 1 … 1 | R | Value of the criterion | XeHLtion |