Template

Show index

Template XeH Laboratory Isolate Organizer 2022‑07‑31 07:54:30

Id2.16.840.1.113883.2.51.10.92Effective Date2022‑07‑31 07:54:30
Statusactive ActiveVersion Label1.0
NameXeHLaboratoryIsolateOrganizerDisplay NameXeH Laboratory Isolate Organizer
Description
The Laboratory Isolate Organizer SHALL be used only if the entry represents a microbiology specimen study with isolates discovered on the specimen. The isolate is represented by the Isolate role played by the Isolate entity. The isolate identification is carried by the code attribute of the Isolate entity.
ContextParent nodes of template element with id 2.16.840.1.113883.2.51.10.92
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 1 template, Uses 10 templates
Used by as NameVersion
2.16.840.1.113883.2.51.10.36Containmentactive XeH Laboratory Report Data Processing Entry (1.0)2021‑10‑07 00:14:07
Uses as NameVersion
1.3.6.1.4.1.19376.1.3.3.1.2.1Containmentactive Non-Human Subject (2017)DYNAMIC
1.3.6.1.4.1.19376.1.3.3.1.3.1Containmentactive Human Patient with Non-Human Subject (2017)DYNAMIC
1.3.6.1.4.1.19376.1.3.3.1.7Containmentactive Laboratory Performer (2017)DYNAMIC
1.3.6.1.4.1.19376.1.3.10.9.2Includeactive Multimedia Embedded Content (2017)DYNAMIC
1.3.6.1.4.1.19376.1.3.10.9.17Containmentactive Author with Name, Addr, Telecom (2017)DYNAMIC
1.3.6.1.4.1.19376.1.5.3.1.4.2Containmentactive IHE Comment Entry (2014)DYNAMIC
2.16.840.1.113883.2.51.10.56Containmentactive XeH Laboratory Observation (1.0)DYNAMIC
2.16.840.1.113883.2.51.10.70Containmentactive XeH Laboratory Battery Organizer (2017)DYNAMIC
2.16.840.1.113883.2.51.10.74Includeactive XeH Lab Results Validator Participant (1.0)DYNAMIC
2.16.840.1.113883.2.51.10.91Includeactive XeH Lab Device Participant (1.0)DYNAMIC
RelationshipAdaptation: template 1.3.6.1.4.1.19376.1.3.1.5 Laboratory Isolate Organizer (2008‑08‑08)
ref
XDLAB-

Adaptation: template 2.16.840.1.113883.10.12.303 CDA Observation (2005‑09‑07)
ref
ad1bbr-
Example
Laboratory Isolate Organizer Example
<organizer classCode="CLUSTER" moodCode="EVN">
  <templateId root="1.3.6.1.4.1.19376.1.3.1.5"/>  <statusCode code="completed"/>  <effectiveTime value="20071108000000.0000-0500"/>  <specimen typeCode="SPC">
    <specimenRole classCode="ISLT">
      <id extension="55584739" root="1.3.6.1.4.1.19376.1.3.4"/>      <specimenPlayingEntity classCode="MIC">
        <code code="79153007" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED-CT" displayName="Salmonella tennessee 6,7,14;z29;1,2,7"/>      </specimenPlayingEntity>
    </specimenRole>
  </specimen>
  <performer typeCode="PRF">
    <templateId root="1.3.6.1.4.1.19376.1.3.3.1.7"/>    <!-- .. -->
  </performer>
  <author typeCode="AUT"> ... </author>  <participant typeCode="AUTHEN">
    <templateId root="1.3.6.1.4.1.19376.1.3.3.1.5"/>    <!-- .. -->
  </participant>
  <participant typeCode="RESP">
    <!-- .. -->
  </participant>
  <participant typeCode="DEV">
    <!-- .. -->
  </participant>
  <component>
    <observation classCode="OBS" moodCode="EVN">
      <templateId root="1.3.6.1.4.1.19376.1.3.1.6"/>      <code code="89029-0" codeSystem="2.16.840.1.113883.6.1" codeSystemName="LOINC" displayName="Microbiology Culture"/>      <!-- .. -->
    </observation>
  </component>
</organizer>
ItemDTCardConfDescriptionLabel
hl7:organizer
XeHLdotsizer
@classCode
cs1 … 1FCLUSTER
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1MXeHLdotsizer
@root
uid1 … 1F2.16.840.1.113883.2.51.10.92
hl7:id
II0 … 1RThe Isolate MAY have a unique identifier from within the laboratory.XeHLdotsizer
hl7:code
CD0 … 1The <code> element SHALL identify the Isolate with a unique international vocabulary. The code, codeSystem, and displayName SHALL be present. You MAY also populate codeSystemName.XeHLdotsizer
hl7:statusCode
CS1 … 1M‘completed’ when all expected results for this isolate are in a final state
‘active’ if some are missing
‘aborted’ if the findings on the isolate did not reach completion. Some results MAY be there.
XeHLdotsizer
 CONF
@code shall be "completed"
or
@code shall be "active"
or
@code shall be "aborted"
hl7:effectiveTime
TS0 … 1RTime of results on this isolate.XeHLdotsizer
Choice … 1Elements to choose from:
hl7:subject
0 … 1subject in case of a non-human subject attached to the isolate
Contains 1.3.6.1.4.1.19376.1.3.3.1.2.1 Non-Human Subject (DYNAMIC)
XeHLdotsizer
@typeCode
cs0 … 1FSBJ
hl7:subject
0 … 1subject in case of a non-human subject attached to the isolate
Contains 1.3.6.1.4.1.19376.1.3.3.1.3.1 Human Patient with Non-Human Subject (DYNAMIC)
XeHLdotsizer
@typeCode
cs0 … 1FSBJ
hl7:specimen
1 … 1Rparticipation of the isolate i.e. the specific sub-specimen on which a microorganism was isolated and cultivatedXeHLdotsizer
@typeCode
cs0 … 1FSPC
hl7:specimenRole
1 … 1RXeHLdotsizer
@classCode
cs0 … 1FSPEC
hl7:id
II0 … 1unique identifier for this isolate, known to the laboratoryXeHLdotsizer
hl7:specimenPlayingEntity
1 … 1RThe entity is a microorganismXeHLdotsizer
@classCode
cs1 … 1FMIC
hl7:code
CE1 … 1RIdentification of the microorganism, in a standard vocabularyXeHLdotsizer
hl7:performer
0 … *performer participation used if specific performer on this isolate, to supersede all performers of higher level.
Contains 1.3.6.1.4.1.19376.1.3.3.1.7 Laboratory Performer (DYNAMIC)
XeHLdotsizer
hl7:author
0 … *author participation used if specific author on this isolate, to supersede all authors of higher level.
Contains 1.3.6.1.4.1.19376.1.3.10.9.17 Author with Name, Addr, Telecom (DYNAMIC)
XeHLdotsizer
hl7:participant
0 … *AUTHEN: The verifier of the battery organizer. In the case where a laboratory report has multiple verifiers. Each verifier is attached to the subset of batteries/observations he or she verified, by the means of a <participant> element.

Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
    XeHLdotsizer
    where [@typeCode='AUTHEN']
    @typeCode
    cs1 … 1FAUTHEN
    Included1 … 1M from 2.16.840.1.113883.2.51.10.74 XeH Lab Results Validator Participant (DYNAMIC)
    hl7:time
    TS1 … 1MXeHLdotspant
    hl7:participantRole
    1 … 1MXeHLdotspant
    @classCode
    cs0 … 1FROL
    hl7:id
    II1 … *RXeHLdotspant
    hl7:code
    CE.IPS (preferred)0 … 1A code, which identifies the profession/competence/specialty of the author when it is a person.
    XeHLdotspant
     CONF
    The value of @code comes preferably from value set 2.16.840.1.113883.11.22.53 IPS Healthcare Professional Roles (DYNAMIC)
    hl7:addr
    AD0 … *XeHLdotspant
    hl7:telecom
    TEL0 … *XeHLdotspant
    hl7:playingEntity
    0 … 1RXeHLdotspant
    hl7:name
    PN1 … 1RXeHLdotspant
    hl7:participant
    0 … *RESP: The person responsible for the provision of the battery. In the case where this battery is subcontracted to an external laboratory, this external laboratory (with its address and telcom) and the actual performer is represented by a <performer> element, whereas the Director of this subcontractor laboratory is carried by the <participant> element being attached to the same level as the <performer> element.

    Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
      XeHLdotsizer
      where [@typeCode='RESP']
      @typeCode
      cs1 … 1FRESP
      hl7:participant
      0 … *DEV: A device or equipment, which was used to produce this battery of results (e.g. an analyzer).

      Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
        XeHLdotsizer
        where [@typeCode='DEV']
        @typeCode
        cs1 … 1FDEV
        Included from 2.16.840.1.113883.2.51.10.91 XeH Lab Device Participant (DYNAMIC)
        hl7:participantRole
        1 … 1MXeHLdotspant
        hl7:id
        II0 … *The UDI Device Identifier MAY be specified as a second id element.
        XeHLdotspant
        hl7:playingDevice
        1 … 1MXeHLdotspant
        hl7:code
        CE.IPS0 … 1Coded product type
        XeHLdotspant
        hl7:manufacturerModelName
        SC0 … 1The element manufacturerModelName“ is intended to be used in the same manner as element “modelNumber” specified in the FHIR device resource. It shall carry model information of the device or software provided in element softwareName
        XeHLdotspant
        hl7:softwareName
        SC1 … 1M
        The element softwareName is the primary element and intended to be used in the same manner as element “deviceName” specified in the FHIR device resource. It should carry the name of the device or software.

        Is SHOULD including the manufacturer name.

        Note: In case of usage for laboratory related documentation (e.g. Laboratory Result Report), the device structure is also used to record "Laboratory Kits" used for the examination.
        XeHLdotspant
        hl7:component
        0 … *RContains 2.16.840.1.113883.2.51.10.70 XeH Laboratory Battery Organizer (DYNAMIC)XeHLdotsizer
        @typeCode
        cs0 … 1FCOMP
        hl7:component
        0 … *RContains 2.16.840.1.113883.2.51.10.56 XeH Laboratory Observation (DYNAMIC)XeHLdotsizer
        @typeCode
        cs0 … 1FCOMP
        hl7:component
        0 … *RMultimedia contentXeHLdotsizer
        @typeCode
        cs0 … 1FCOMP
        Included from 1.3.6.1.4.1.19376.1.3.10.9.2 Multimedia Embedded Content (DYNAMIC)
        hl7:observationMedia
        Multdotstent
        @classCode
        cs1 … 1FOBS
        @moodCode
        cs1 … 1FEVN
        hl7:value
        1 … 1MMultdotstent
        @mediaType
        cs1 … 1R
         CONF
        @mediaType shall be "image/gif"
        or
        @mediaType shall be "image/jpeg"
        or
        @mediaType shall be "image/png"
        or
        @mediaType shall be "image/bmp"
        @representation
        cs1 … 1FB64
        hl7:component
        0 … *RContains 1.3.6.1.4.1.19376.1.5.3.1.4.2 IHE Comment Entry (DYNAMIC)XeHLdotsizer
        @typeCode
        cs0 … 1FCOMP
         Schematron assertrolered error 
         testhl7:component 
         MessageSpecimenObservationCluster _Organizer SHALL contain at least one of Battery, Observation, Multimedia or Annotation comment.