Id2.16.840.1.113883.10.20.1.7Effective Date2007‑04‑01
Statuspending Under pre-publication reviewVersion Label
NameMedicalEquipmentSectionDisplay NameMedical equipment section
Description

3.10 Medical Equipment

The template identifier for the medical equipment section is 2.16.840.1.113883.10.20.1.7.

The Medical Equipment section defines a patient’s implanted and external medical devices and equipment that their health status depends on, as well as any pertinent equipment or device history. This section is also used to itemize any pertinent current or historical durable medical equipment (DME) used to help maintain the patient’s health status. All pertinent equipment relevant to the diagnosis, care, and treatment of a patient should be included.

The ASTM CCR defines medical equipment using the same data objects and constraints as for Medications.

CONF-371: CCDSHOULD contain exactly one and SHALL NOT contain more than one Medical Equipment section (templateId 2.16.840.1.113883.10.20.1.7). The Medical Equipment section SHALL contain a narrative block, and SHOULD contain clinical statements. Clinical statements SHOULD include one or more supply activities (templateId 2.16.840.1.113883.10.20.1.34) and MAY include one or more medication activities (templateId 2.16.840.1.113883.10.20.1.24).

3.10.1 Section conformance

CONF-372: The medical equipment section SHALL contain Section / code.
CONF-373: The value for “Section / codeSHALL be “46264-8” “History of medical device use” 2.16.840.1.113883.6.1 LOINC STATIC.
CONF-374: The medical equipment section SHALL contain Section / title.
CONF-375: Section / titleSHOULD be valued with a case-insensitive language-insensitive text string containing “equipment”.

3.10.2 Clinical statement conformance

The ASTM CCR defines medical equipment using the same data objects and constraints as for Medications. See section 3.9 Medications for details.

ContextParent nodes of template element with id 2.16.840.1.113883.10.20.1.7
ClassificationCDA Section Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 1 transaction and 1 template, Uses 4 templates
Used by as NameVersion
2.16.840.1.113883.3.1937.777.4.4.1Transactionfinal Continuity of Care Document (CCD) (Release 1.1)2013‑01‑31
2.16.840.1.113883.10.20.1Containmentpending CCD v1.0 Templates Root2007‑04‑01
Uses as NameVersion
2.16.840.1.113883.3.1937.777.4.10.3Containmentpending CCD Subject (Body)DYNAMIC
2.16.840.1.113883.10.20.1.24Containmentpending Medication activityDYNAMIC
2.16.840.1.113883.10.20.1.34Containmentpending Supply activityDYNAMIC
2.16.840.1.113883.10.20.1.40Containmentpending CommentDYNAMIC
RelationshipSpecialization: template 2.16.840.1.113883.10.12.201 (2005‑09‑07)
ItemDTCardConfDescriptionLabel
hl7:section
Medidotstion
@classCode
cs0 … 1 
 CONF
The value of @classCode shall be drawn from value set 2.16.840.1.113883.1.11.20215 ActClassDocumentSection (DYNAMIC)
@moodCode
cs0 … 1 
 CONF
The value of @moodCode shall be drawn from value set 2.16.840.1.113883.1.11.20267 ActMoodEventOccurrence (DYNAMIC)
hl7:templateId
II1 … 1Medidotstion
@root
uid1 … 1F2.16.840.1.113883.10.20.1.7
hl7:id
II0 … 1Medidotstion
hl7:code
CE1 … 1MCONF‑372 / CONF‑373
@code
CONF1 … 1F46264-8
@codeSystem
1 … 1F2.16.840.1.113883.6.1
hl7:title
ST1 … 1MCONF‑374 / CONF‑375
 Schematron assertrolered error 
 testcontains(lower-case(.),'equipment') 
 MessageCONF-375: Section / title SHOULD be valued with a case-insensitive language-insensitive text string containing “equipment”. 
hl7:text
SD.TEXT1 … 1MCONF‑371
hl7:confidentialityCode
CE0 … 1Medidotstion
 CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.16926 x_BasicConfidentialityKind (DYNAMIC)
hl7:languageCode
CS0 … 1Medidotstion
 CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.11526 HumanLanguage (DYNAMIC)
hl7:subject
0 … 1Contains 2.16.840.1.113883.3.1937.777.4.10.3 CCD Subject (Body) (DYNAMIC)Medidotstion
hl7:entry
1 … *Contains 2.16.840.1.113883.10.20.1.34 Supply activity (DYNAMIC)CONF‑371
@typeCode
cs1 … 1R
 CONF
The value of @typeCode shall be drawn from value set 2.16.840.1.113883.1.11.19446 x_ActRelationshipEntry (DYNAMIC)
@contextConductionInd
bl0 … 1 
hl7:entry
0 … *Contains 2.16.840.1.113883.10.20.1.24 Medication activity (DYNAMIC)CONF‑371
@typeCode
cs1 … 1R
 CONF
The value of @typeCode shall be drawn from value set 2.16.840.1.113883.1.11.19446 x_ActRelationshipEntry (DYNAMIC)
@contextConductionInd
bl0 … 1 
hl7:entry
0 … *Contains 2.16.840.1.113883.10.20.1.40 Comment (DYNAMIC)CONF‑502
@typeCode
cs1 … 1R
 CONF
The value of @typeCode shall be drawn from value set 2.16.840.1.113883.1.11.19446 x_ActRelationshipEntry (DYNAMIC)
@contextConductionInd
bl0 … 1