Template

Show index

Template Author 2016‑05‑23

Id2.16.756.5.30.1.1.1.1.3.9.1.10.2.5Effective Date2016‑05‑23
Statusdraft DraftVersion Label2017
NameCH_LREP_AUTODisplay NameAuthor
DescriptionAt least one author MUST be declared. The author CAN be a person or a software module.
ClassificationCDA Header Level Template
Open/ClosedOpen (other than defined elements are allowed)
RelationshipSpecialization: template 2.16.840.1.113883.10.12.102 CDA author (2005‑09‑07)
ref
ad1bbr-
ItemDTCardConfDescriptionLabel
hl7:author
1 … *RAt least one author MUST be declared.CH_LdotsAUTO
hl7:functionCode
CE0 … 1CAt least one of the listed authors must be a laboratory specialist.CH_LdotsAUTO
@displayName
st1 … 1FMedical and pathology laboratory technicians
@codeSystemName
st1 … 1FISCO-08
@codeSystem
oid1 … 1F2.16.840.1.113883.2.9.6.2.7
@code
cs1 … 1F3212
hl7:time
TS.CH.TZ1 … 1RDate and time of the laboratory report creation.CH_LdotsAUTO
hl7:assignedAuthor
1 … 1RThe author CAN be a person or a software module.CH_LdotsAUTO
 Schematron assertrolered error 
 testnot(assignedAuthoringDevice/softwareName) or (representedOrganization) 
 MessageFor device authors the element representedOrganization is required. 
 Schematron assertrolered error 
 test(telecom[@use='PUB' and starts-with(@value,'tel:+']) and (telecom[@use='PUB' and starts-with(@value,'mailto:']) 
 MessageA public telephone number in the international format and a public eMail address are required. 
 Schematron assertrolered error 
 test(addr[@use='PUB']) 
 MessageA public address is required. 
hl7:id
II1 … *R The specification of GS1 GLN is required. If it is not (yet) known, this must be declared using nullFlavor.
For persons whose personal GLN must be specified.
For software modules the GLN of the laboratory MUST be specified.
CH_LdotsAUTO
@nullFlavor
cs0 … 1FNAV
 Temporarily unknown, will be filled later.
@extension
st0 … 1 The GS1 GLN.
@root
cs0 … 1F2.51.1.3
 OID for GS1 GLN.
 Schematron assertrolered error 
 test(@root='2.51.1.3' and @extension) or (@nullFlavor='NAV') 
 MessageEither the GS1 GLN or nullFlavor='NAV' is required 
hl7:addr
AD1 … *RAddress of the laboratory.CH_LdotsAUTO
hl7:telecom
TEL1 … *RMeans of communication of the laboratory (phone, eMail, ...).CH_LdotsAUTO
Choice0 … 1Elements to choose from:
hl7:assignedPerson
All persons and organizations, MUST according to XD-LAB contain name, addr and telecom.
Contains
alertError: Cannot find template "2.16.756.5.30.1.1.10.9.18" (DYNAMIC)
CH_LdotsAUTO
hl7:assignedAuthoringDevice
The name of the software module MUST be specified if the author is a software module.
Contains
alertError: Cannot find template "2.16.756.5.30.1.1.1.1.3.9.1.10.9.2" (DYNAMIC)
CH_LdotsAUTO
hl7:representedOrganization
0 … 1All persons and organizations, MUST according to XD-LAB contain name, addr and telecom.
Contains
alertError: Cannot find template "2.16.756.5.30.1.1.10.9.19" (DYNAMIC)
CH_LdotsAUTO