Template

Show index

Template Specimen Collection 2017‑03‑24 16:18:41

Id2.16.756.5.30.1.1.10.4.11
ref
ch-palm-
Effective Date2017‑03‑24 16:18:41
Statusdraft DraftVersion Label2017
Namechpalm_entry_SpecimenCollectionDisplay NameSpecimen Collection
DescriptionLaboratory reports MAY contain information on the specimen. If there are more than one specimen associated to the order, then this item occurs multiple times.
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
RelationshipSpecialization: template 2.16.840.1.113883.10.12.306 CDA Procedure (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.2 (2016‑07‑05)
ref
ch-palm-
ItemDTCardConfDescriptionLabel
hl7:procedure
chpadotstion
@classCode
cs1 … 1FPROC
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1Mchpadotstion
@root
uid1 … 1F1.3.6.1.4.1.19376.1.3.1.2
hl7:id
II0 … 1An ID for this item CAN be filled for traceability.chpadotstion
@extension
st1 … 1RMUST contain the ID itself. The ID MUST be unique within the system that issued the ID.
@root
uid1 … 1RMUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
hl7:code
CD1 … 1MLOINC specimen collection code.chpadotstion
@code
CONF1 … 1F33882-2
@codeSystem
1 … 1F2.16.840.1.113883.6.1
@displayName
1 … 1FCollection date of Unspecified specimen
@codeSystemName
1 … 1FLOINC
Included1 … 1 from 2.16.756.5.30.1.1.10.9.14 Narrative Text Reference (DYNAMIC)
The human-readable text MUST be generated automatically from the structured information of this element.
The text element MUST contain the reference to the corresponding text in the human readable part, ONLY.
hl7:text
ED1 … 1MCDA‑CH V2
hl7:reference
TEL1 … 1MThe reference to the corresponding text in the human readable part must be specified by reference to content[@ID]: reference[@value='#xxx']CDA‑CH V2
@value
1 … 1RReference to the narrative part of the section in the format '#xxx', where xxx is the ID of the corresponding element.
 Schematron assertrolered error 
 teststarts-with(@value,'#') 
 MessageThe @value attribute content MUST conform to the format '#xxx', where xxx is the ID of the corresponding 'content' element. 
 Variable letNameidvalue 
 Valuesubstring-after(@value,'#') 
 Schematron assertrolered error 
 testancestor::hl7:structuredBody//*[@ID=$idvalue] 
 MessageNo narrative text found for this reference (no content element within this document has an ID that corresponds to '<value-of select="$idvalue"/>'). 
hl7:effectiveTime
IVL_TS.CH.TZ1 … 1 Timestamp (e.g., for simple blood sampling) or period (e.g., 24 hour urine test) of the specimen collection or specimen creation.
  • Timestamp:
    Is declared using @value. Minimum accuracy of the value: Date (the time of the day is OPTIONAL).
  • Period:
    Is declared using low/@value and high/@value. Accuracy of the value: Date and time with hour and minute.
chpadotstion
@nullFlavor
cs0 … 1FUNK
 If the moment in time of the sampling is not known, nullFlavor='UNK' MUST be used.
 Schematron assertrolered error 
 test(@nullFlavor='UNK') or (string-length(@value)>7) or ((low/@nullFlavor='UNK' or string-length(low/@value)>11) and (high/@nullFlavor='UNK' or string-length(high/@value)>11)) 
 MessageA precision of date is required. 
hl7:targetSiteCode
CD0 … 1 This CAN be used to indicate the anatomical position of the specimen collection. This is particularly relevant in microbiology (e.g., when the sample was removed with a swab from the left foot).
The HL7 vocabulary ActSite contains anatomical locations of organisms that may be at the center of the action.
chpadotstion
@displayName
st1 … 1RThe displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
@codeSystemName
st1 … 1FActSite
@codeSystem
oid1 … 1F2.16.840.1.113883.5.1052
@code
cs1 … 1RThe code MUST be specified.
hl7:performer
0 … 1This can be used to specify who performed the specimen collection.
Contains 2.16.756.5.30.1.1.10.4.7 Laboratory Performer - performer Containment (DYNAMIC)
chpadotstion
hl7:participant
1 … 1MThe information on the specimen MUST be declared.
Contains 2.16.756.5.30.1.1.10.4.24 Specimen collection - participant Containment (DYNAMIC)
chpadotstion
hl7:entryRelationship
0 … 1This MAY be used to indicate when the sample has arrived at the laboratory.
Contains 2.16.756.5.30.1.1.10.4.12 Specimen Received (DYNAMIC)
chpadotstion
@typeCode
cs1 … 1FCOMP
hl7:entryRelationship
0 … * This MAY be used to indicate observations of the specimen collection.
This allows to provide information to the laboratory, that are important e.g. for a 24-hour urine test:
  • Collection period for 24 hour urine test: @code='13362-9' (Collection duration of Urine), @value='24', @unit='h'
  • Collected volume (urine quantity): @code='19153-6' (Volume in Urine collected for unspecified duration), @value: urine quantity, @unit: UCUM unit of urine quantity (e.g. ml, dl or l)

Contains 2.16.756.5.30.1.1.10.4.3 Laboratory Observation (DYNAMIC)
chpadotstion
@typeCode
cs1 … 1FCOMP