Template

Show index

Template Specimen Received 2017‑03‑24 16:20:04

Id2.16.756.5.30.1.1.10.4.12
ref
ch-palm-
Effective Date2017‑03‑24 16:20:04
Statusdraft DraftVersion Label2017
Namechpalm_entry_SpecimenReceivedDisplay NameSpecimen Received
DescriptionA laboratory report MAY contain information on the reception of the specimen at the laboratory.
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
RelationshipSpecialization: template 2.16.840.1.113883.10.12.301 CDA Act (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.3 (2016‑07‑05)
ref
ch-palm-
ItemDTCardConfDescriptionLabel
hl7:act
chpadotsived
@classCode
cs1 … 1FACT
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1Mchpadotsived
@root
uid1 … 1F1.3.6.1.4.1.19376.1.3.1.3
hl7:id
II1 … 1R The delivered identification of specimen at the customer MUST be declared.
If specimen identification is not available, nullFlavor='ASKU' MUST be used. In this case @root and @extension are NOT ALLOWED.
TODO schematron to check these busines rules.
chpadotsived
@nullFlavor
cs0 … 1FASKU
 If specimen identification is not available, nullFlavor='ASKU' MUST be used.
@extension
st1 … 1RMUST contain the specimen identification as issued by the customer. The number MUST be unique within the system that issued the number.
@root
uid1 … 1RMUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
hl7:code
CD1 … 1Rchpadotsived
@code
CONF0 … 1FSPRECEIVE
@codeSystem
0 … 1F1.3.5.1.4.1.19376.1.5.3.2
@codeSystemName
0 … 1FIHEActCode
@displayName
0 … 1FReceive Time
Included1 … 1 from 2.16.756.5.30.1.1.10.9.14 Narrative Text Reference (DYNAMIC)
The human-readable text MUST be generated automatically from the structured information of this element.
The text element MUST contain the reference to the corresponding text in the human readable part, ONLY.
hl7:text
ED1 … 1MCDA‑CH V2
hl7:reference
TEL1 … 1MThe reference to the corresponding text in the human readable part must be specified by reference to content[@ID]: reference[@value='#xxx']CDA‑CH V2
@value
1 … 1RReference to the narrative part of the section in the format '#xxx', where xxx is the ID of the corresponding element.
 Schematron assertrolered error 
 teststarts-with(@value,'#') 
 MessageThe @value attribute content MUST conform to the format '#xxx', where xxx is the ID of the corresponding 'content' element. 
 Variable letNameidvalue 
 Valuesubstring-after(@value,'#') 
 Schematron assertrolered error 
 testancestor::hl7:structuredBody//*[@ID=$idvalue] 
 MessageNo narrative text found for this reference (no content element within this document has an ID that corresponds to '<value-of select="$idvalue"/>'). 
hl7:effectiveTime
IVL_TS.CH.TZ1 … 1RTimestamp of the specimen reception at the laboratory. Minimum accuracy of the value: Date and time with hour and minute.chpadotsived
 Schematron assertrolered error 
 teststring-length(@value)>11 
 MessageA precision of date and time of day with at least hour and minute is required.