Item | DT | Card | Conf | Description | Label |
---|
hl7:observation
| | | | | chpation |
@classCode
| cs | 1 … 1 | F | CASE |
@moodCode
| cs | 1 … 1 | F | EVN |
hl7:templateId
| II | 1 … 1 | M | | chpation |
@root
| uid | 1 … 1 | F | 1.3.6.1.4.1.19376.1.3.1.1.2 |
hl7:id
| II | 0 … * | R | The number of the case to which the examinations belong in this section MUST be declared. Multiple case numbers CAN be specified. | chpation |
@extension
| st | 1 … 1 | R | MUST contain the case identification itself. The case identification MUST be unique within the system that issued the ID. |
@root
| uid | 1 … 1 | R | MUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED. |
hl7:code
| CE | 1 … 1 | R | The type of the case MUST be declared with a code. LOINC (2.16.840.1.113883.6.1) or SNOMED-CT (2.16.840.1.113883.6.96) codes or values from the HL7 vocabulary ObservationType (2.16.840.1.113883.1.11.16226) SHOULD be used. | chpation |
@displayName
| st | 1 … 1 | R | The displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set. |
@codeSystemName
| st | 1 … 1 | R | The name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED. |
@codeSystem
| oid | 1 … 1 | R | The OID of the code system MUST be specified. |
@code
| cs | 1 … 1 | R | The code MUST be specified. |
hl7:statusCode
| CS | 1 … 1 | M | The status 'completed' means the patient has been associated with the given case number. The status 'aborted' means the patient was associated with the case number in error. | chpation |
| CONF | |
hl7:effectiveTime
| IVL_TS.CH.TZ | 0 … 1 | | MAY contain the period of validity of the case. | chpation |
hl7:low
| TS.CH.TZ | 1 … 1 | R | Start of the period. If it is not known, nullFavor='UNK' MUST be used. | chpation |
hl7:high
| TS.CH.TZ | 1 … 1 | R | End of the period. If it is not known, nullFavor='UNK' MUST be used. | chpation |
hl7:value
| CE | 1 … 1 | R | A not further specified precision of the case MUST be declared according to XD-LAB with data type 'CE'. If no further precision is known, nullFavor='UNK' MUST be used. | chpation |
| Schematron assert | role | error | |
| test | (@xsi:type'CE' and @code and @codeSystem) or (@nullFlavor='NAV') | |
| Message | Either a code with its code system or nullFlavor='UNK' is required. | |