Template Notifiable Condition - Significant Pathogen 2020‑06‑26

Id2.16.756.5.30.1.1.10.4.86Effective Date2020‑06‑26
Statusactive ActiveVersion Label2020
Namecdachlrep_entry_NotifiableConditionSignificantPathogenDisplay NameNotifiable Condition - Significant Pathogen
DescriptionCoding of a significant pathogen.
ContextParent nodes of template element with id 2.16.756.5.30.1.1.10.4.86
LabelCDA‑CH‑LREP
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 1 transaction and 5 templates, Uses 0 templates
Used by as NameVersion
2.16.756.5.30.1.1.1.1.3.9.77.1.4.2Transactionpending CDA-CH-LREP - General Laboratory Report (2018)2018‑03‑06 18:38:46
2.16.756.5.30.1.1.10.1.10linkactive General Laboratory Report (2020)2020‑06‑26
2.16.756.5.30.1.1.10.3.76linkactive Laboratory Report Item Section - coded (2020)2020‑06‑26
2.16.756.5.30.1.1.10.3.77linkactive Laboratory Speciality Section - coded (2020)2020‑06‑26
2.16.756.5.30.1.1.10.4.88Containmentactive Notification Organizer - Significant Pathogens (2020)2020‑06‑26
2.16.756.5.30.1.1.10.4.118linkactive Laboratory Report Data Processing Entry (2020)2020‑06‑26
RelationshipSpecialization: template 2.16.840.1.113883.10.12.303 CDA Observation (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.1.1 Notifiable Condition (DYNAMIC)
ref
XDLAB-
Example
Example
<observation classCode="COND" moodCode="EVN">
  <templateId root="2.16.756.5.30.1.1.10.4.86"/>  <templateId root="2.16.756.5.30.1.1.10.4.14"/>  <templateId root="1.3.6.1.4.1.19376.1.3.1.1.1"/>  <code code="170516003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Notification of disease">
    <qualifier>
      <name code="246087005" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Source of specimen"/>      <value code="116154003" codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT" displayName="Patient"/>    </qualifier>
  </code>
  <statusCode/>  <effectiveTime>
    <low value="20180311203542"/>  </effectiveTime>
  <value xsi:type="CE" displayName="Escherichia coli serotype [Identifier] in Isolate" codeSystemName="LOINC" codeSystem="2.16.840.1.113883.6.1" code="20789-4"/></observation>
ItemDTCardConfDescriptionLabel
hl7:observation
CDA‑dotsLREP
@classCode
cs1 … 1FCOND
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1MCDA‑dotsLREP
@root
uid1 … 1F2.16.756.5.30.1.1.10.4.86
hl7:templateId
II1 … 1MCDA‑dotsLREP
@root
uid1 … 1F2.16.756.5.30.1.1.10.4.14
hl7:templateId
II1 … 1MCDA‑dotsLREP
@root
uid1 … 1F1.3.6.1.4.1.19376.1.3.1.1.1
hl7:id
II0 … *An ID for this item MAY be filled for traceability.CDA‑dotsLREP
@root
uid1 … 1RMUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
@extension
st0 … 1 Contains the ID itself. The ID MUST be unique within the system that issued the ID.
hl7:code
CD1 … 1RCDA‑dotsLREP
@code
cs1 … 1F170516003
@codeSystem
oid1 … 1F2.16.840.1.113883.6.96
@codeSystemName
st1 … 1FSNOMED CT
@displayName
st1 … 1FNotification of disease
hl7:qualifier
CR1 … 1RA qualification of the notifiable condition MUST be specified.CDA‑dotsLREP
hl7:name
CV1 … 1RQualifies the code with the source of specimenCDA‑dotsLREP
@code
cs1 … 1F246087005
@codeSystem
oid1 … 1F2.16.840.1.113883.6.96
@codeSystemName
st1 … 1FSNOMED CT
@displayName
st1 … 1FSource of specimen
hl7:value
CD1 … 1RIdentifies the specimen source of the condition – patient, food, water, ...CDA‑dotsLREP
@code
cs1 … 1RThe OID of the code system MUST be specified.
@codeSystem
oid1 … 1RThe code MUST be specified.
@codeSystemName
st1 … 1RThe name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st1 … 1RThe displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
hl7:statusCode
CS1 … 1M

The status 'completed' means the patient has been associated with the given notifiable condition.

The status 'aborted' means the patient was associated with the notifiable condition in error.

CDA‑dotsLREP
 CONF
The value of @code shall be drawn from value set 1.3.6.1.4.1.19376.1.3.11.2 ActStatusAbortedCompleted (DYNAMIC)
hl7:effectiveTime
IVL_TS.CH.TZ1 … 1RTimestamp of the sampling.CDA‑dotsLREP
hl7:value
CE1 … 1RA code that defines the reportable state MUST be specified. If no code is known, nullFlavor='NA' MUST be used.CDA‑dotsLREP
@nullFlavor
cs0 … 1FNA
 If no code is known, nullFlavor='NA' MUST be used.
@code
cs0 … 1 The code MUST be specified.
@codeSystem
oid0 … 1 The OID of the code system MUST be specified.
@codeSystemName
st0 … 1 The name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st0 … 1 The displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
 Schematron assertrolered error 
 test(@xsi:type='CE' and @code and @codeSystem) or (@nullFlavor='NA') 
 MessageEither a code with its code system or nullFlavor='NA' is required.