Template

Show index

Template Laboratory Battery Organizer 2019‑08‑20

Id2.16.756.5.30.1.1.10.4.19
ref
ch-palm-
Effective Date2019‑08‑20
Statusactive ActiveVersion Label2019
Namechpalm_entry_LaboratoryBatteryOrganizerDisplay NameLaboratory Battery Organizer
Description
According to IHE XD-LAB, the Laboratory Battery Organizer allows the grouping of results.
Laboratory reports MUST contain at least one result group with at least one result.
The grouping of multiple results (Observations) into multiple result groups (Laboratory Battery Organizers) is permitted.
ContextParent nodes of template element with id 2.16.756.5.30.1.1.10.4.19
LabelIHE PalM TF3 Rev.10, 6.3.4.12
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 3 transactions and 8 templates, Uses 12 templates
Used by as NameVersion
2.16.756.5.30.1.127.77.1.4.5Transactionpending CDA-CH-VACD - Immunization Recommendation Request (2018)2018‑04‑10 18:08:44
2.16.756.5.30.1.127.77.1.4.6Transactionpending CDA-CH-VACD - Immunization Recommendation Response (2018)2018‑04‑10 18:09:59
2.16.756.5.30.1.127.77.1.4.7Transactionpending CDA-CH-VACD - Vaccination Record (2018)2018‑04‑10 18:10:49
2.16.756.5.30.1.1.10.1.17linkactive Immunization Recommendation Request (2020)2020‑06‑26
2.16.756.5.30.1.1.10.1.18linkactive Immunization Recommendation Response (2020)2020‑06‑26
2.16.756.5.30.1.1.10.1.19linkactive Vaccination Record (2020)2020‑06‑26
2.16.756.5.30.1.1.10.3.3linkactive Laboratory Speciality Section - coded (2019)2019‑08‑20
2.16.756.5.30.1.1.10.3.5linkactive Laboratory Report Item Section - coded (2019)2019‑08‑20
2.16.756.5.30.1.1.10.4.4Containmentactive Laboratory Report Data Processing Entry (2019)2019‑08‑20
2.16.756.5.30.1.1.10.4.17Containmentactive Laboratory Isolate Organizer (2019)2019‑08‑20
2.16.756.5.30.1.1.10.4.118Containmentactive Laboratory Report Data Processing Entry (2020)2020‑06‑26
Uses as NameVersion
2.16.756.5.30.1.1.10.4.2Containmentactive Annotation Comments (2016)DYNAMIC
2.16.756.5.30.1.1.10.4.3Containmentactive Laboratory Observation (2020)DYNAMIC
2.16.756.5.30.1.1.10.4.5Containmentactive Non-Human Subject - subject Containment (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.6Containmentactive Human Patient with Non-Human Subject - subject Containment (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.7Containmentactive Laboratory Performer - performer Containment (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.8Containmentactive Laboratory Results Validator - participant Containment (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.9Containmentactive Responsible Party - participant Containment (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.10Containmentactive Device - participant Containment (2020)DYNAMIC
2.16.756.5.30.1.1.10.4.11Containmentactive Specimen Collection (2019)DYNAMIC
2.16.756.5.30.1.1.10.4.18Containmentactive Multimedia Embedded Content (2020)DYNAMIC
2.16.756.5.30.1.1.10.4.29Containmentactive External document (2017)DYNAMIC
2.16.756.5.30.1.1.10.9.16Containmentactive Author Compilation with name, addr and telecom (2020)DYNAMIC
RelationshipSpecialization: template 2.16.840.1.113883.10.12.305 CDA Organizer (2005‑09‑07)
ref
ad1bbr-

Specialization: template 1.3.6.1.4.1.19376.1.3.1.4 Laboratory Battery Organizer (DYNAMIC)
ref
XDLAB-
Example
Example
<organizer classCode="BATTERY" moodCode="EVN">
  <templateId root="2.16.756.5.30.1.1.10.4.19"/>  <templateId root="1.3.6.1.4.1.19376.1.3.1.4"/>  <id root="2.999" extension="your id"/>  <code displayName="displayName" codeSystemName="codeSystemName" codeSystem="1.2.3.999" code="cs"/>  <statusCode/>  <effectiveTime value="20180320134438+0100"/></organizer>
ItemDTCardConfDescriptionLabel
hl7:organizer
IHE PalM TF3 Rev.10, 6.3.4.12
@classCode
cs1 … 1FBATTERY
@moodCode
cs1 … 1FEVN
hl7:templateId
II1 … 1MIHE PalM TF3 Rev.10, 6.3.4.12
@root
uid1 … 1F2.16.756.5.30.1.1.10.4.19
hl7:templateId
II1 … 1MIHE PalM TF3 Rev.10, 6.3.4.12
@root
uid1 … 1F1.3.6.1.4.1.19376.1.3.1.4
hl7:id
II0 … 1An ID for this item MAY be filled for traceability.IHE PalM TF3 Rev.10, 6.3.4.12
@root
uid1 … 1RMUST contain the OID of the system that issued the ID. OIDs of code systems, which are published in the public OID registry for the Swiss health care system (oid.refdata.ch) are REQUIRED. Others are NOT ALLOWED.
@extension
st0 … 1 Contains the ID itself. The ID MUST be unique within the system that issued the ID.
hl7:code
CD0 … 1 If the results in this result group are associated to a codable group (e.g., LOINC Code 55429-5 for 'short blood count panel'), then the code SHOULD be specified. The code system is not further specified. LOINC (2.16.840.1.113883.6.1) or SNOMED CT (2.16.840.1.113883.6.96) codes or values from the HL7 vocabulary ObservationType (2.16.840.1.113883.1.11.16226) SHOULD be used.
If this result group contains any other results, then the code SHOULD be omitted.
IHE PalM TF3 Rev.10, 6.3.4.12
@code
cs1 … 1RThe code MUST be specified.
@codeSystem
oid1 … 1RThe OID of the code system MUST be specified.
@codeSystemName
st1 … 1RThe name of the code system MUST be specified for tracking purposes. However, processing is NOT ALLOWED.
@displayName
st1 … 1RThe displayName of the code MUST be specified for tracking purposes. However, processing is NOT ALLOWED. Instead, a processing system is to display a user readable language translation of the code from the value set.
hl7:statusCode
CS1 … 1M

The status 'completed' means that all expected results for this results group are present and in a final state.

The status 'aborted' means that the examinations had to be aborted. Some results MAY be available.

IHE PalM TF3 Rev.10, 6.3.4.12
 CONF
The value of @code shall be drawn from value set 1.3.6.1.4.1.19376.1.3.11.2 ActStatusAbortedCompleted (DYNAMIC)
hl7:effectiveTime
IVL_TS.CH.TZ1 … 1RTimestamp or period of findings (physiologically relevant period) for all results in this result group.IHE PalM TF3 Rev.10, 6.3.4.12
@value
TS.CH.TZ0 … 1 Timestamp. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used.
hl7:low
TS.CH.TZ0 … 1Start of the period. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used.IHE PalM TF3 Rev.10, 6.3.4.12
 Schematron assertrolered error 
 teststring-length(@value)>11 
 MessageA precision of date and time of day with at least hour and minute is required. 
hl7:high
TS.CH.TZ0 … 1End of the period. Accuracy of the value: Date and time with hour and minute. If it is not known, nullFavor='UNK' must be used.IHE PalM TF3 Rev.10, 6.3.4.12
 Schematron assertrolered error 
 teststring-length(@value)>11 
 MessageA precision of date and time of day with at least hour and minute is required. 
 Schematron assertrolered error 
 test@nullFlavor='UNK' or @value or (hl7:low and hl7:high) 
 MessageEither the timestamp or the period of the findings MUST be declared. If it is not known, nullFavor='UNK' must be used. 
Choice0 … 1
IF this result group is based on a specimen of a non-human material, the subject element MUST be declared.
Elements to choose from:
hl7:subject
0 … 1Contains 2.16.756.5.30.1.1.10.4.5 Non-Human Subject - subject Containment (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
hl7:subject
0 … 1Contains 2.16.756.5.30.1.1.10.4.6 Human Patient with Non-Human Subject - subject Containment (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
hl7:performer
0 … *This CAN be used to indicate who has performed the test. This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.7 Laboratory Performer - performer Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:author
0 … *This CAN be used to indicate who has documented the result. This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.9.16 Author Compilation with name, addr and telecom (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FAUT
Choice0 … *
This CAN be used to identify other parties:
  • Who has verified the result (AUTHEN).
  • Which external laboratory has delivered the result (RESP).
  • Which device (analyzer) was used to determine the result (DEV).
Elements to choose from:
hl7:participant
0 … *Who has verified the result (AUTHEN). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.8 Laboratory Results Validator - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:participant
0 … *Which external laboratory has delivered the result (RESP). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.9 Responsible Party - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
hl7:participant
0 … *Which device (analyzer) was used to determine the result (DEV). This information supersedes any information recorded at higher level.
Contains 2.16.756.5.30.1.1.10.4.10 Device - participant Containment (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
Choice0 … *Elements to choose from:
hl7:component
0 … *Contains 2.16.756.5.30.1.1.10.4.11 Specimen Collection (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FCOMP
hl7:component
0 … *Contains 2.16.756.5.30.1.1.10.4.3 Laboratory Observation (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FCOMP
hl7:component
0 … *Contains 2.16.756.5.30.1.1.10.4.18 Multimedia Embedded Content (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FCOMP
hl7:component
0 … *Contains 2.16.756.5.30.1.1.10.4.2 Annotation Comments (DYNAMIC)IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FCOMP
hl7:reference
0 … *This CAN be used to make reference to an external document.
Contains 2.16.756.5.30.1.1.10.4.29 External document (DYNAMIC)
IHE PalM TF3 Rev.10, 6.3.4.12
@typeCode
cs1 … 1FREFR