Template

Show index

Template Laboratory Device 2016‑07‑05

Id1.3.6.1.4.1.19376.1.3.10.9.19
ref
XDLAB-
Effective Date2016‑07‑05
Statusactive ActiveVersion Label2017
NameIHEDeviceDisplay NameLaboratory Device
Description

This module declares a laboratory device (analyzer). It is consistent with the CDA standard regarding participant and requires in addition the name, addr and telecom for all participants.

ClassificationTemplate type not specified
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 3 transactions and 26 templates, Uses 0 templates
Used by as NameVersion
2.16.840.1.113883.2.4.3.11.60.121.4.2.13.1Transactionfinal Registration2020‑09‑01
2.16.840.1.113883.2.4.3.11.60.7.4.2.13.1Transactiondeprecated Registration (4.0)2017‑09‑04
2.16.840.1.113883.2.4.3.11.60.7.4.2.13.1Transactionfinal Registration (4.1)2017‑12‑31
1.3.6.1.4.1.19376.1.3.1.4linkactive Laboratory Battery Organizer (2017)2008‑08‑08
1.3.6.1.4.1.19376.1.3.1.5linkactive Laboratory Isolate Organizer (2017)2008‑08‑08
1.3.6.1.4.1.19376.1.3.1.6linkactive Laboratory Observation (2017)2008‑08‑08
1.3.6.1.4.1.19376.1.3.3linkactive Sharing Laboratory Reports (XD-LAB) Content Module (2017)2016‑07‑05
1.3.6.1.4.1.19376.1.3.10.2.2Containmentactive XD-LAB Author (2017)2016‑07‑05
1.3.6.1.4.1.19376.1.3.10.9.17Containmentactive Author with Name, Addr, Telecom (2017)2016‑07‑05
2.16.840.1.113883.2.4.3.11.60.7.10.1linkretired Laboratory Battery or Isolate2017‑10‑16 14:59:25
2.16.840.1.113883.2.4.3.11.60.7.10.1linkpending Laboratory Battery or Isolate2021‑08‑30
2.16.840.1.113883.2.4.3.11.60.7.10.2linkretired Laboratory Battery Organizer (Specimen)2017‑10‑16
2.16.840.1.113883.2.4.3.11.60.7.10.2linkpending Laboratory Battery Organizer (Specimen)2021‑08‑30 14:46:35
2.16.840.1.113883.2.4.3.11.60.7.10.2linkcancelled Laboratory Battery Organizer (Specimen)2021‑10‑27 16:59:56
2.16.840.1.113883.2.4.3.11.60.7.10.4linkretired Laboratory Isolate Organizer (Specimen)2017‑10‑16
2.16.840.1.113883.2.4.3.11.60.7.10.4linkpending Laboratory Isolate Organizer (Specimen)2021‑08‑30 14:45:51
2.16.840.1.113883.2.4.3.11.60.7.10.4linkcancelled Laboratory Isolate Organizer (Specimen)2021‑10‑27 17:00:31
2.16.840.1.113883.2.4.3.11.60.25.10.51linkdraft Lab2Zorg - Sharing Laboratory Reports (XD-LAB) (2017)2018‑06‑05 14:37:04
2.16.840.1.113883.2.4.3.11.60.25.10.51linkdraft Lab2Zorg - Sharing Laboratory Reports NL (XD-LAB) (2020)2022‑03‑30
2.16.840.1.113883.2.4.3.11.60.25.10.52linkcancelled Laboratory Specialty Section (2017)2018‑06‑05 14:38:48
2.16.840.1.113883.2.4.3.11.60.25.10.52linkactive Laboratory Specialty Section2021‑10‑27
2.16.840.1.113883.2.4.3.11.60.25.10.52linkdraft Laboratory Specialty Section2022‑12‑20 14:13:14
2.16.840.1.113883.2.4.3.11.60.25.10.53linkretired Laboratory Report Data Processing Entry (2017)2018‑06‑05 14:42:09
2.16.840.1.113883.2.4.3.11.60.25.10.53linkpending Laboratory Report Data Processing Entry (2017)2021‑10‑27
2.16.840.1.113883.2.4.3.11.60.25.10.54linkcancelled Laboratory Report Item Section (2017)2018‑06‑05 14:44:20
2.16.840.1.113883.2.4.3.11.60.25.10.54linkactive Laboratory Report Item Section (2017)2021‑10‑27
2.16.840.1.113883.2.4.3.11.60.121.10.51linkactive Laboratory organizer or CDA2022‑03‑30
2.16.840.1.113883.2.4.3.11.60.121.10.56Containmentdraft XD-LAB Author NL (2020)2022‑03‑30
2.16.840.1.113883.2.4.3.11.60.121.10.59Containmentactive Author with Name, Addr, Telecom NL (2017)2022‑03‑30
RelationshipSpecialization: template 2.16.840.1.113883.10.12.315 CDA Device (2005‑09‑07)
ref
ad1bbr-
ItemDTCardConfDescriptionLabel
hl7:softwareName
SC1 … 1R

This module declares a laboratory device (analyzer). It is consistent with the CDA standard regarding participant and requires in addition the name (softwareName in this case) for all participants.

IHEDevice