Template

Show index

Template IHE Procedure Entry 2016‑09‑28 10:37:28

Id1.3.6.1.4.1.19376.1.5.3.1.4.19
ref
IHE-PCC-
Effective Date2016‑09‑28 10:37:28
Statusactive ActiveVersion Label2014
NameIHEProcedureEntryDisplay NameIHE Procedure Entry
DescriptionThe procedure entry is used to record procedures that have occurred, or which are planned for in the future.
ContextParent nodes of template element with id 1.3.6.1.4.1.19376.1.5.3.1.4.19
Label6.3.4.33
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 0 transactions and 18 templates, Uses 1 template
Used by as NameVersion
1.3.6.1.4.1.12559.11.10.1.3.1.2.5Containmentdraft Section Coded Results2013‑12‑20
1.3.6.1.4.1.12559.11.10.1.3.1.2.5Containmentretired eHDSI Coded Results2020‑04‑16 12:13:16
1.3.6.1.4.1.19376.1.5.3.1.1.9.1Containmentactive IHE Proposed Procedure Section (2016)2017‑03‑27 09:05:24
1.3.6.1.4.1.19376.1.5.3.1.1.9.3Containmentactive IHE Proposed Anesthesia Section (2016)2017‑03‑27 08:53:22
1.3.6.1.4.1.19376.1.5.3.1.1.9.40Containmentactive IHE Procedure Care Plan Section (2016)2017‑03‑24 10:20:07
1.3.6.1.4.1.19376.1.5.3.1.1.13.2.11Containmentactive IHE Procedures and Interventions Section (2014)2015‑10‑05 16:12:10
1.3.6.1.4.1.19376.1.5.3.1.1.20.2.1Containmentactive IHE Provider Orders Section (2016)2017‑03‑24 10:55:21
1.3.6.1.4.1.19376.1.5.3.1.1.20.2.1.9999Containmentactive IHE Notifications, Alerts, and Reminders Section (2016)2017‑03‑24 14:07:53
1.3.6.1.4.1.19376.1.5.3.1.3.12Containmentdraft Section Coded List of Surgeries2013‑12‑20
1.3.6.1.4.1.19376.1.5.3.1.3.12Containmentactive IHE Coded List of Surgeries section (2014)2016‑09‑28 10:10:47
1.3.6.1.4.1.19376.1.5.3.1.3.12Containmentretired eHDSI List of Surgeries2020‑04‑16 12:10:44
1.3.6.1.4.1.19376.1.5.3.1.3.28Containmentactive IHE Coded Results Section (2014)2015‑10‑05 17:52:06
1.3.6.1.4.1.19376.1.5.3.1.3.30Containmentactive IHE Coded Hospital Studies Summary Section (2016)2017‑03‑16 09:57:56
1.3.6.1.4.1.19376.1.5.3.1.3.36Containmentactive IHE Coded Care Plan Section (2016)2017‑03‑24 10:39:19
1.3.6.1.4.1.19376.1.7.3.1.1.15.3.2Containmentactive IHE Hearing Screening Coded Results (2016)2017‑03‑24 12:33:27
2.16.756.5.30.1.1.10.3.28Containmentpending Provider Orders Section - coded (2016)2016‑11‑11
2.16.756.5.30.1.1.10.3.31Containmentpending Results Section - coded (2016)2016‑11‑11
2.16.756.5.30.1.1.10.3.64Containmentdraft Results Section - coded (2018)2017‑09‑13 20:20:53
Uses as NameVersion
1.3.6.1.4.1.19376.1.5.3.1.4.4.1Containmentpending IHE Internal Reference Entry (2014)DYNAMIC
RelationshipSpecialization: template 2.16.840.1.113883.10.12.306 CDA Procedure (2005‑09‑07)
ref
ad1bbr-
ItemDTCardConfDescriptionLabel
hl7:procedure
6.3.4.33
@classCode
cs1 … 1FPROC
@moodCode
cs1 … 1R
hl7:templateId
II1 … 1M6.3.4.33
@root
uid1 … 1F1.3.6.1.4.1.19376.1.5.3.1.4.19
hl7:templateId
II0 … 1R6.3.4.33
@root
uid1 … 1F2.16.840.1.113883.10.20.1.29
hl7:templateId
II0 … 1R6.3.4.33
@root
uid1 … 1F2.16.840.1.113883.10.20.1.25
hl7:id
II1 … *M6.3.4.33
hl7:code
CD1 … 1R6.3.4.33
hl7:text
ED1 … 1M6.3.4.33
hl7:reference
TEL1 … 1M6.3.4.33
hl7:statusCode
CS1 … 1M6.3.4.33
 CONF
@code shall be "completed"
or
@code shall be "active"
or
@code shall be "aborted"
or
@code shall be "cancelled"
hl7:effectiveTime
IVL_TS0 … 16.3.4.33
hl7:priorityCode
CE0 … 1R6.3.4.33
hl7:approachSiteCode
CD0 … *6.3.4.33
hl7:targetSiteCode
CD0 … *6.3.4.33
hl7:entryRelationship
0 … *Contains 1.3.6.1.4.1.19376.1.5.3.1.4.4.1 IHE Internal Reference Entry (DYNAMIC)6.3.4.33
@typeCode
cs1 … 1FCOMP
@inversionInd
bl1 … 1Ftrue
hl7:entryRelationship
0 … *Contains 1.3.6.1.4.1.19376.1.5.3.1.4.4.1 IHE Internal Reference Entry (DYNAMIC)6.3.4.33
@typeCode
cs1 … 1FRSON
 Schematron assertrolered error 
 test@moodCode='EVN' or @moodCode='INT' 
 MessageThe moodCode attribute SHALL have the value EVN or INT 
 Schematron assertrolered error 
 test(@moodCode='EVN' and hl7:templateId/@root='2.16.840.1.113883.10.20.1.29') or (@moodCode='INT' and hl7:templateId/@root='2.16.840.1.113883.10.20.1.25') 
 MessageWhen the procedure is in event mood (moodCode='EVN'), this entry conforms to the CCD template 2.16.840.1.113883.10.20.1.29, and when in intent mood, this entry conforms to the CCD template 2.16.840.1.113883.10.20.1.25 
 Schematron assertrolered error 
 test((@moodCode='INT') and (effectiveTime or priorityCode)) or (@moodCode='EVN') 
 MessagepriorityCode shall be present in INT mood when effectiveTime is not provided, it may be present in other moods.