Template

Show index

Template Device Compilation with name 2018‑04‑18

Id2.16.756.5.30.1.1.10.9.21Effective Date2018‑04‑18
Statusactive ActiveVersion Label2017
Namecdach_other_DeviceCompilationWithNameDisplay NameDevice Compilation with name
Description
Reusable template wherever a device with required name is used in a CDA-CH V2 document. CDA-CH V2 derivatives, i.e. Swiss exchange formats MAY use this template by either reference or specialisation.
A device is either a physical device (e.g. analyzer with which laboratory results are determined) or a software (e.g. laboratory information system, in which laboratory results are documented).
LabelCDA‑CH V2
ClassificationTemplate type not specified
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 3 transactions and 16 templates, Uses 0 templates
Used by as NameVersion
2.16.756.5.30.1.127.77.2.4.3Transactiondraft CDA-CH - NonXMLBody (2020)2017‑11‑10 09:44:03
2.16.756.5.30.1.127.77.2.4.4Transactioncancelled CDA-CH - StructuredBody Enhanced (2018)2018‑02‑12 17:54:58
2.16.756.5.30.1.127.77.2.4.2Transactiondraft CDA-CH - StructuredBody (2020)2017‑11‑10 09:35:28
2.16.756.5.30.1.1.10.1.9linkretired CDA-CH v2.0 - structuredBody (2017)2018‑04‑18
2.16.756.5.30.1.1.10.1.9linkactive CDA-CH v2.1 - structuredBody (2020)2019‑10‑17 15:22:41
2.16.756.5.30.1.1.10.1.12linkactive CDA-CH v2.0 - nonXMLBody (2017)2018‑04‑18
2.16.756.5.30.1.1.10.1.14linkactive CDA-CH v2.0 - structuredBody enhanced (2018)2018‑04‑18
2.16.756.5.30.1.1.10.2.59Containmentactive Author (2020)2020‑06‑26
2.16.756.5.30.1.1.10.2.74Containmentdraft Author (2018)2017‑09‑08 11:42:14
2.16.756.5.30.1.1.10.4.10Containmentactive Device - participant Containment (2020)2019‑08‑20
2.16.756.5.30.1.1.10.9.16Containmentretired Author Compilation with name, addr and telecom (2017)2018‑04‑18
2.16.756.5.30.1.1.10.9.16Containmentactive Author Compilation with name, addr and telecom (2020)2019‑10‑24 16:13:06
2.16.756.5.30.1.1.10.9.23Containmentretired Author (2017)2018‑04‑18
2.16.756.5.30.1.1.10.9.23Containmentactive Author (2020)2019‑09‑12 13:48:28
2.16.756.5.30.1.1.10.9.36linkactive CDA-CH v2.0 Header Template Compilation (2017)2018‑04‑18
2.16.756.5.30.1.1.10.9.48Containmentretired Author Compilation with name (2017)2018‑04‑18
2.16.756.5.30.1.1.10.9.48Containmentactive Author Compilation with name (2020)2019‑10‑24 15:57:29
2.16.756.5.30.1.1.10.9.52Containmentdraft SCDO Author (2017)2018‑06‑26 18:00:12
2.16.756.5.30.1.1.10.9.54Containmentactive Author Compilation with id, name, addr and telecom (2020)2020‑04‑28 12:02:52
RelationshipSpecialization: template 2.16.840.1.113883.10.12.315 CDA Device (2005‑09‑07)
ref
ad1bbr-
Example
Software
<manufacturerModelName>4.0</manufacturerModelName><softwareName>New generation KIS</softwareName>
Example
Physical device
<manufacturerModelName>w872</manufacturerModelName><softwareName>Pipette laboratory analyzer</softwareName>
ItemDTCardConfDescriptionLabel
hl7:manufacturerModelName
SC0 … 1The model name of the device MAY be declared.CDA‑CH V2
hl7:softwareName
SC1 … 1R The name of the device MUST be declared.
Note: Altough this element is called softwareName, it contains also the name of physical devices (e.g. laboratory analyzer).
CDA‑CH V2