Value Set

Show index

Value Set Diagnostic Report status 2022‑02‑17 13:09:02

Id2.16.840.1.113883.3.1937.777.24.11.77Effective Date2022‑02‑17 13:09:02
Canonical URIhttp://hl7.org/fhir/ValueSet/diagnostic-report-status
Statusdraft DraftVersion Label
NameDiagnosticReportStatusDisplay NameDiagnostic Report status
CopyrightThis artefact includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/getsnomed-ct or info@snomed.org.
2 Source Code Systems
2.16.840.1.113883.6.96 - SNOMED Clinical Terms - FHIR: http://snomed.info/sct - HL7 V2: SCT
2.16.840.1.113883.5.1050 - Acknowledgement Condition - FHIR: http://terminology.hl7.org/CodeSystem/v3-AcknowledgementCondition
Level/ TypeCodeDisplay NameCode SystemDescription
0‑L
registered
Registered
Acknowledgement ConditionThe existence of the report is registered, but there is nothing yet available.
0‑L
partial
Partial
Acknowledgement ConditionThis is a partial (e.g. initial, interim or preliminary) report: data in the report may be incomplete or unverified.
1‑L
preliminary
Preliminary
Acknowledgement ConditionVerified early results are available, but not all results are final.
0‑L
final
Final
Acknowledgement ConditionThe report is complete and verified by an authorized person.
0‑L
amended
Amended
Acknowledgement ConditionSubsequent to being final, the report has been modified. This includes any change in the results, diagnosis, narrative text, or other content of a report that has been issued.
1‑L
corrected
Corrected
Acknowledgement ConditionSubsequent to being final, the report has been modified to correct an error in the report or referenced results.
1‑L
appended
Appended
Acknowledgement ConditionSubsequent to being final, the report has been modified by adding new content. The existing content is unchanged.
0‑L
cancelled
Cancelled
Acknowledgement ConditionThe report is unavailable because the measurement was not started or not completed (also sometimes called "aborted").
0‑L
entered-in-error
Entered-in-error
Acknowledgement ConditionThe report has been withdrawn following a previous final release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "cancelled" rather than "entered-in-error".).
0‑L
unknown
Unknown
SNOMED Clinical Terms
The authoring/source system does not know which of the status values currently applies for this observation. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, but the authoring/source system does not know which.

Legenda: Type L=leaf, S=specializable, A=abstract, D=deprecated. NullFlavor OTH (other) suggests text in originalText. HL7 V3: NullFlavors to appear in @nullFlavor attribute instead of @code.