Help
Login
Busy
Search
CDA-CH-LREP - Laboratory report - Issues

 
Select object
 
falsehide
Results (1 / 1)
Id Issue Status Priority Type Date Assigned To Label
1 Laboratory Organizer content incorrect in specification Closed Normal Incident 2020-05-20 11:48:29 Tony Schaller
 
Incident Laboratory Organizer content incorrect in specification
Id cdachlrep-issue-1
Status Closed
Priority Normal
Last Tracking 2020-05-20 11:48:29  by  Tony Schaller
Current Assignee Tony Schaller
    
Concerns
/
-
/
-
Events
Assignment 2020-05-20 11:48:29 : Assigned To Tony Schaller by Tony Schaller
Tracking Closed 2018-09-07 15:50:08 : Tracking by Tony Schaller
Edited by Tony Schaller ( 2020-05-20 11:50:02 ) Tony Schaller ( 2020-05-20 11:55:41 ) Tony Schaller ( 2020-05-20 11:58:58 ) Tony Schaller ( 2020-05-20 12:04:05 )
Description
Finding:

- https://art-decor.org/art-decor/decor-templates--ch-palm-?section=templates&id=2.16.756.5.30.1.1.10.4.19 states entryRelationship for components. This is wrong

Suggestion:

- This has to be changed from entryRelationship  to component. And this is also valid for all derivates/specifications/versions of this template!

Elements to choose from:


Further explanation:
See https://www.ihe.net/uploadedFiles/Documents/PaLM/IHE_PaLM_TF_Vol3.pdf, Page 60 (6.3.4.12 Laboratory Battery Organizer 1.3.6.1.4.1.19376.1.3.1.4)

Resolution:

This issue is a CH-PALM issue and should have been reported in the CH-PALM issues.

Already done in the new version of 2019‑07‑30 17:27:26:

No Specialiosations found. But also verified in 2.16.756.5.30.1.1.10.4.87 (Laboratory Battery Organizer - Antibiogram).
    
Labels
Preview Code HTML color Display Name Description