Help
Login
Busy
Search
Consolidated CDA - Templates

 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
true50
Medication Activity (V2)
false
Issues (7)
false
Change Request Status = Closed ( ccda-issue-102 ): Erratum-1106 Incorrect OID on ActStatus value set
Type Change Request Status Change Request Status = Closed Priority Normal
Events
Tracking / Status = Closed 2017-10-03 21:24:14 : Tracking by Lisa Nelson
Assignment 2017-09-30 20:42:54 : Assigned To Didi Davis by Lisa Nelson
Description
The conformance statement on statusCode/@code is missing...Our template does not match with the erratum assumptions.  Nor does it match with the C-CDA R2.1 pdf.  Need to review with Didi.

Reviewed and now we know how to make the additional StatusCode/@code  attribute.
Tracking / Status = Open 2017-09-30 20:41:20 : Tracking by Lisa Nelson
Assignment 2017-09-22 02:28:01 : Assigned To Lisa Nelson by Lisa Nelson
Tracking / Status = Open 2017-09-22 02:28:00 : Tracking by Lisa Nelson
Description

Finding:
-Incorrect OID on ActStatus value set 

Suggestion:
-Prior Value Set OID: 2.16.840.1.113883.1.11.159331
-Value Set OID after update:  2.16.840.1.113883.1.11.15933

Further explanation:

1098-32360
Change Request Status = Closed ( ccda-issue-115 ): Erratum-1272 Remove "IVL_TS" for effectiveTime (CONF:1098-7508
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (DT) Data types 
Events
Tracking / Status = Closed 2017-10-16 16:27:24 : Tracking by Lisa Nelson
 
 DT 
Tracking / Status = Feedback needed 2017-10-12 20:03:10 : Tracking by Lisa Nelson
 
 DT 
Description
I tried just removing the datatype of IVL_TS, but then got a resource error trying to save the template.  Will see if Didi recalls how to do this one, or try to find the other example of what we did.
Assignment 2017-09-30 19:23:08 : Assigned To dr Kai U. Heitmann by Lisa Nelson
Description
Datatype Issue
Tracking / Status = Open 2017-09-30 19:22:50 : Tracking by Lisa Nelson
Description
The effective element does not permit me to modify the datatype to just be TS.  Would i pick datatype not-set?  Or, modify by hand in Temple editor?
Assignment 2017-09-22 03:42:39 : Assigned To Lisa Nelson by Lisa Nelson
Tracking / Status = Open 2017-09-22 03:42:38 : Tracking by Lisa Nelson
Description
Finding:

-Remove "IVL_TS" from Table 337 for effectiveTime (CONF:1098-7508), and correct the schematron rule so it does not require effectiveTime to be IVL_TS.

Suggestion:

-Prior Conformance:
effectiveTime 1…1 SHALL IVL_TS 1098-7508
-Conformance After Update:
effectiveTime 1…1 SHALL           1098-7508

Further explanation:

-CONF:1098-7508

Change Request Status = Cancelled ( ccda-issue-148 ): Erratum-1381 doseQuantity and administratinUnitCode should never both be present
Type Change Request Status Change Request Status = Cancelled Priority Normal
Events
Tracking / Status = Cancelled 2017-09-28 21:49:59 : Tracking by Lisa Nelson
Description
Erratum was removed from the set of errata to be included in the R2.1 errata package.
Assignment 2017-09-28 15:35:45 : Assigned To dr Kai U. Heitmann by Lisa Nelson
Description
Conditional Conformance
Assignment 2017-09-26 18:39:14 : Assigned To Lisa Nelson by Lisa Nelson
Tracking / Status = Open 2017-09-26 18:39:13 : Tracking by Lisa Nelson
Description
Finding:
-doseQuantity and administratinUnitCode should never both be present

Suggestion:
-Prior Conformance:
None
-Conformance After Update:
The doseQuanity/@unit and administrationUnitCode/@code SHALL NOT [0..0] both be present 

Further explanation:
-32951
Change Request Status = Closed ( ccda-issue-152 ): Erratum-1276 Created Medication Route Value Set to align with FHIR, CQM, NCPDP. Current set included incorrect concepts
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (VALUESET) Value Set Issue 
Events
Tracking / Status = Closed 2017-10-23 22:33:34 : Tracking by Lisa Nelson
 
 VALUESET 
Assignment 2017-10-16 22:55:40 : Assigned To Lisa Nelson by Lisa Nelson
 
 VALUESET 
Tracking / Status = In Progress 2017-10-16 22:55:10 : Tracking by Lisa Nelson
 
 VALUESET 
Tracking / Status = In Progress 2017-10-16 22:54:49 : Tracking by Lisa Nelson
Assignment 2017-09-28 15:27:53 : Assigned To Didi Davis by Lisa Nelson
Assignment 2017-09-26 19:21:30 : Assigned To Lisa Nelson by Lisa Nelson
Tracking / Status = Open 2017-09-26 19:21:29 : Tracking by Lisa Nelson
Description

Finding:
-Created Medication Route Value Set to align with FHIR, CQM, NCPDP. Current set included incorrect concepts.

Suggestion:
-Prior Conformance:
10. MAY contain zero or one [0..1] routeCode, which SHALL be selected from ValueSet Medication Route FDA urn:oid:2.16.840.1.113883.3.88.12.3221.8.7 DYNAMIC 
-Conformance After Update:
10. MAY contain zero or one [0..1] routeCode, which SHALL be selected from ValueSet Medication Route urn:oid:2.16.840.1.113762.1.4.1099.12 DYNAMIC

Further explanation:

-8839
Change Request Status = Closed ( ccda-issue-179 ): CS-20180129-01 doseQuantity should allow nullFlavor
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (CS) Customer Support 
Events
Tracking / Status = Closed 2018-06-04 21:07:23 : Tracking by Didi Davis
 
 CS 
Description
Issue was not closed when customer informed.  Verified the issue was addressed by rerunning the original document provided.  https://gazellecontent.sequoiaproject.org/EVSClient/detailedResult.seam?type=CDA&oid=1.3.6.1.4.1.12559.11.28.1641

This 
https://gazellecontent.sequoiaproject.org/EVSClient/detailedResult.seam?type=CDA&oid=1.3.6.1.4.1.12559.11.28.13274  rerun proves that ccda212121 no longer errors with NULL in element. 
Assignment 2018-01-31 02:28:11 : Assigned To Abderrazek Boufahja by Lisa Nelson
Tracking / Status = In Progress 2018-01-31 02:28:00 : Tracking by Lisa Nelson
Description
Issue was resolved by removing the mandatory flag for the doseQuantity element. 

Resolution was reported to the customer.
Assignment 2018-01-31 02:24:09 : Assigned To Lisa Nelson by Lisa Nelson
Tracking / Status = Open 2018-01-31 02:24:08 : Tracking by Lisa Nelson
Description
Finding:

-I am seeing an unexpected error when attempting to validate a CCD using the Sequoia C-CDA R2.1 validator.  It is not allowing a nullFlavor for the “doseQuantity” element in the “Medication Activity (V2)” template.  However, the C-CDA R2.1 spec doesn’t state that nullFlavor isn’t allowed, nor does it require the @code attribute.  See info and screenshots below.

 

File Name: patient_CCDA_CCD_R2_1_altered.xml

OID : 1.3.6.1.4.1.12559.11.28.1641

Schematron :  N/A (Version N/A)

Schematron Validation Result :  N/A

Validation Date :  1/29/18 6:01:04 PM (CET GMT+0100)

Model Based Validator :  HL7 - C-CDA R2.1 - Meaningful Use Stage 3 (Version N/A)

Model Based Validation Result :  FAILED SC

Permanent link :  https://gazellecontent.sequoiaproject.org/EVSClient/detailedResult.seam?type=CDA&oid=1.3.6.1.4.1.12559.11.28.1641

Data Visibility :  Private - Owned By kstevenson / DOD

 

 

 

 

I believe the nullFlavor should be allowed for the “doseQuantity” element since it isn’t specifically not allowed and none of the attributes of the doseQuantity element are specifically required.

Suggestion:

-

Further explanation:

-

Change Request Status = Closed ( ccda-issue-195 ): Errata 1276 - add translation on routeCode
Type Change Request Status Change Request Status = Closed Priority High
Events
Tracking / Status = Closed 2018-07-02 22:39:07 : Tracking by Lisa Nelson
Description
We replaced the incorrect value set oid with the correct one: 2.16.840.1.113762.1.4.1099.12
Tracking / Status = In Progress 2018-06-25 19:25:29 : Tracking by Lisa Nelson
Description
This template is locked and I can't edit it.
Tracking / Status = In Progress 2018-05-30 16:58:18 : Tracking by Didi Davis
Description

Text from the May 2018 updated Volume 2 HL7 documentation with Errata #1276 applied on page 600
2.16.840.1.113883.10.20.22.4.16 (2014-06-09) Medication Activity (V2) 

SHOULD contain zero or one [0..1] routeCode, which SHALL be selected from ValueSet Medication Route FDA urn:oid:2.16.840.1.113883.3.88.12.3221.8.7 DYNAMIC (CONF:1098-7514).

a. The routeCode, if present, SHOULD contain zero or more [0..*] translation, which SHOULD be selected from ValueSet Medication Route urn:oid:2.16.840.1.113762.1.4.1099.12 DYNAMIC (CONF:1098-32950).


Assignment 2018-05-07 23:44:48 : Assigned To Abderrazek Boufahja by Lisa Nelson
Tracking / Status = Open 2018-05-07 21:43:56 : Tracking by Lisa Nelson
Description
Finding:

-Errata 1276 - add translation on routeCode

Suggestion:

Medication Activity (V2)

1.    SHOULD contain zero or one [0..1] routeCode, which SHALL be selected from ValueSet Medication Route FDA urn:oid:2.16.840.1.113883.3.88.12.3221.8.7 DYNAMIC (CONF:1098-7514).

a.    The routeCode, if present, SHOULD contain zero or more [0..*] translation, which SHALL be selected from ValueSet Medication Route urn:oid:2.16.840.1.113762.1.4.1099.12 DYNAMIC (CONF:1098-32950).

Further explanation:

-

Incident Status = Open ( phcrg-issue-31 ): unable to gernerate diagram
Type Incident Status Incident Status = Open Priority Normal
Events
Tracking / Status = Open 2015-11-03 16:58:20 : Tracking by Eric M Haas
Description
Finding:

-unable to gernerate diagram

Suggestion:

-check in with AD team

Further explanation:

-

 
 
Busy