Help
Login
Busy
Search
CH-PCC - Templates

 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
true50
Social History Observation
false
History (6)
Date Author Status Type
2020-06-26 13:16:41 Tony Schaller Draft version
2020-06-23 14:43:25 Tony Schaller Draft version
2020-05-28 11:08:10 Tony Schaller Draft version
2020-05-27 11:38:09 Tony Schaller Draft version
2020-05-07 12:09:34 Tony Schaller Draft version
2020-05-07 12:09:29 Tony Schaller Draft version
false
Issues (1)
false
Change Request Status = Closed ( ch-pcc-issue-1 ): hl7:value appears twice in Social History Observation
Type Change Request Status Change Request Status = Closed Priority Normal
Events
Assignment 2019-09-02 13:21:39 : Assigned To Tony Schaller by Oliver Egger
Tracking / Status = Closed 2019-09-02 13:21:38 : Tracking by Oliver Egger
Description
Finding:

there should be only a hl7:value element below the the hl7:repeatNumber, not above

hl7:value
ANY1 … *RIHE PCC TF2 Rev.11, 6.3.4.24
@xsi:type
cs0 … 1FANY
hl7:repeatNumber
IVL_INTNPIHE PCC TF2 Rev.11, 6.3.4.24
hl7:value
0 … *IHE PCC TF2 Rev.11, 6.3.4.24
Suggestion:

remove the first hl7:value

Further explanation:

IHE PCC TF2 Rev.11, 6.3.4.24

Resolution:
Done as suggested:
 hl7:value
ANY0 … *IHE PCC TF2 Rev.11, 6.3.4.24

 
 
Busy