epSOS CDA relatedDocument (repository: epsos-)
false
Issues (1)
false
Change Request Status = Open ( epsos-issue-209 ): Constraint applied to relatedDocument
Type Change Request Status Change Request Status = Open Priority Lowest
Events
Tracking / Status = Open 2017-10-27 17:42:06 : Tracking by Giorgio Cangioli
Description
Finding:

The CDA standard claims
"A conformant CDA document can have a single relatedDocument with typeCode "APND"; a single relatedDocument with typeCode "RPLC"; a single relatedDocument with typeCode "XFRM"; a combination of two relatedDocuments with typeCodes "XFRM" and "RPLC"; or a combination of two relatedDocuments with typeCodes "XFRM" and "APND".

No other combinations are allowed."

Suggestion:

This constraint is not captured by the current specifications.
Add an explicit assertion to check this.

Further explanation:

-

 
 