Help
Login
Busy
Search
epSOS - Templates

 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
true50
Immunizations
false
History (3)
Date Author Status Type
2018-03-28 10:50:09 Mathias Ghys Draft version
2017-08-01 18:59:00 Christof Gessner Draft version
2017-05-17 13:52:07 Giorgio Cangioli Draft version
false
Issues (10)
false
Change Request Status = Open ( epsos-issue-64 ): Assign an epSOS specific template ID
Type Change Request Status Change Request Status = Open Priority Normal
Current Labels
 
 (TID) Template ID 
 
 (TBA) To be approved 
Events
Tracking / Status = Open 2017-08-01 19:05:36 : Tracking by Christof Gessner
 
 TID 
 
 TBA 
Description
I support this. id is mandatory in IHE template, but this does not make sense here (changed it to 0..1 R).
Tracking / Status = Open 2016-07-13 14:53:22 : Tracking by Giorgio Cangioli
 
 TID 
Tracking / Status = Open 2016-03-29 12:57:38 : Tracking by Giorgio Cangioli
 
 M4 
 
 TID 
Tracking / Status = Open 2016-03-17 18:48:20 : Tracking by Giorgio Cangioli
 
 M4 
Assignment 2015-11-18 16:57:05 : Assigned To Giorgio Cangioli by Giorgio Cangioli
 
 M2 
Tracking / Status = Open 2015-11-09 17:42:28 : Tracking by Giorgio Cangioli
Description
Finding:

the OID used is the IHE PCCC template

Suggestion:

assign an epSOS specific template id in order to correctly identify the applied constrained

Further explanation:

keep on-the-wire backword compatibility

Request for Information/Education Status = Closed ( epsos-issue-65 ): routeofAdm and apporach site
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Current Labels
 
 (M2) Milestone 2 
Events
Tracking / Status = Closed 2017-05-17 13:52:29 : Tracking by Giorgio Cangioli
 
 M2 
Description
Removed the binding 
Assignment 2016-03-01 12:30:23 : Assigned To Dr. Kai U. Heitmann by Giorgio Cangioli
 
 M2 
Tracking / Status = Open 2016-03-01 12:29:47 : Tracking by Giorgio Cangioli
 
 M1 
Description
remove Voc bindings for those elements
Tracking / Status = Open 2015-11-18 16:57:36 : Tracking by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-09 17:59:54 : Tracking by Giorgio Cangioli
Description
Finding:

the epSOS specs derived form the IHE PCC template mention RoA and approach site that are not actually used in epSOS for immun- There are not value set defined for Approach site

Suggestion:

maybe we can leave the RoA since we may suppose to reuse the value set used for medication;

to be better understood what to do with approach site

Further explanation:

-

Request for Information/Education Status = Closed ( epsos-issue-66 ): approachSiteCode
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Current Labels
 
 (M3) Milestone 3 
Events
Tracking / Status = Closed 2017-05-17 14:13:26 : Tracking by Giorgio Cangioli
 
 M3 
Description
the approachSiteCode seems to be no more in the template...assumed closed
Assignment 2016-03-17 11:22:20 : Assigned To Dr. Kai U. Heitmann by Dr. Kai U. Heitmann
 
 M3 
Tracking / Status = Open 2015-11-18 16:58:50 : Tracking by Giorgio Cangioli
 
 M1 
Description
to be resolved woith issue#65
Tracking / Status = Open 2015-11-17 10:21:30 : Tracking by Giorgio Cangioli
Description
Finding:

The approachSiteCodeseems requests the usage of the 2.16.840.1.113883.5.1052 code system. This element is not actually used in epSOS (even if included in the documentation)

Suggestion:

Evaluate if to mantain the constarin as it is or to remove it

Further explanation:

-

Change Request Status = Closed ( epsos-issue-67 ): doseQuantity duplicated
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2015-11-19 15:56:37 : Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
doseQuantity is now only one element with data type RTO_PQ_PQ
Tracking / Status = Open 2015-11-18 16:59:22 : Tracking by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-17 10:25:41 : Tracking by Giorgio Cangioli
Description
Finding:

doseQuantity appear twice as PQ ratio and PQ IVL.

Suggestion:

remove the PQ ratio. Tio be cosnidered that we cosnider to have the doseQuantity as PQ and not only as IVL_PQ

Further explanation:

-

Request for Information/Education Status = Closed ( epsos-issue-68 ): 2.16.840.1.113883.10.20.1.46 Position Of Vaccination
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Current Labels
 
 (M3) Milestone 3 
Events
Tracking / Status = Closed 2016-03-17 11:26:57 : Tracking by Dr. Kai U. Heitmann
 
 M3 
Description
Element removed
Assignment 2016-03-17 11:23:44 : Assigned To Dr. Kai U. Heitmann by Dr. Kai U. Heitmann
 
 M3 
Description
approachSiteCode shall not have a code system binding
Tracking / Status = Open 2015-11-18 16:59:37 : Tracking by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-17 10:43:21 : Tracking by Giorgio Cangioli
Description
Finding:

2.16.840.1.113883.10.20.1.46 Position Of Vaccination (Dynamic)


Even if referred in the text this is not expected to be used for epSOS

Suggestion:
evaluate if it better to leave as it is or to remove this part

Further explanation:

-

Request for Information/Education Status = Closed ( epsos-issue-69 ): adverse reactions in immunization
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Current Labels
 
 (M2) Milestone 2 
Events
Tracking / Status = Closed 2016-02-23 13:17:25 : Tracking by Giorgio Cangioli
 
 M2 
Tracking / Status = Open 2015-11-30 16:29:40 : Tracking by Giorgio Cangioli
 
 M2 
Tracking / Status = Open 2015-11-18 17:00:03 : Tracking by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-17 10:46:33 : Tracking by Giorgio Cangioli
Description
Finding:

the tempalte refer an adverse reactions entry that is not actuaklly used in epSOS

Suggestion:

to be evalauted if to remove or to leave it. In the last case the template actually used for the allergies adevrese reaction should be used

Further explanation:

-

Request for Information/Education Status = Closed ( epsos-issue-70 ): Product information duplicated ?
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2016-03-17 17:39:43 : Tracking by Giorgio Cangioli
 
 M1 
Description
removed the "duplicated" relationship with product
Assignment 2015-11-18 17:00:21 : Assigned To Giorgio Cangioli by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-17 10:50:41 : Tracking by Giorgio Cangioli
Description
Finding:

The template seems to have a duplciataed relationship with the product entry .

Suggestion:

clarify what the second relationshiop is actually referring to.... and if it is used

Further explanation:

-

Change Request Status = Closed ( epsos-issue-83 ): DoseQuantity DT to be fixed
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (M1) Milestone 1 
Events
Tracking / Status = Closed 2015-11-24 18:48:27 : Tracking by Dr. Kai U. Heitmann
 
 M1 
Description
This was definitely entered/defined in error. doseQuantity is now a IVL_PQ as defined in the generic CDA.
Assignment 2015-11-20 19:43:46 : Assigned To Dr. Kai U. Heitmann by Giorgio Cangioli
 
 M1 
Tracking / Status = Open 2015-11-20 19:43:45 : Tracking by Giorgio Cangioli
 
 M1 
Description
Finding: the DT should not be RTO_PQ_PQ (see issue #67) but IVL_PQ or  PQ

Change Request Status = Closed ( epsos-issue-203 ): editorial change: clarification concerning ActCode codesystem
Type Change Request Status Change Request Status = Closed Priority Normal
Events
Assignment 2017-08-01 18:56:13 : Assigned To Christof Gessner by Christof Gessner
Tracking / Status = Closed 2017-08-01 18:56:12 : Tracking by Christof Gessner
Description
Finding:

- Description doesn't make it clear that codeSystem IHEActCode (1.3.5.1.4.1.19376.1.5.3.2) must be used, and not generic HL7 ActCode (2.16.840.1.113883.5.4)

Suggestion:

- add text to clarify

Further explanation:

-

Change Request Status = Closed ( epsos-issue-267 ): Remove the textual constraint to the CCD template for the Allergies reaction observation
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (TBA) To be approved 
Events
Tracking / Status = Closed 2018-03-28 10:52:56 : Tracking by Mathias Ghys
 
 TBA 
Description
Textual constraint removed from the template.
I also removed it from the example in the observation for the immunizations. Since there it was not in the description, but only in the example and this is very confusing.
Assignment 2018-03-28 10:42:29 : Assigned To Mathias Ghys by Mathias Ghys
 
 TBA 
Tracking / Status = Open 2018-03-28 10:42:28 : Tracking by Mathias Ghys
 
 TBA 
Description
Finding:

- After the working session with the eHDSI solution provider and Christof Gessner it was considered to remove the dependency from the CCD template 2.16.840.1.113883.10.20.1.54. This is required by some text in the Allergies reaction observation. There is no formal reason to keep it. The constraint is just in textual form, therefore it is not tested in the validation.
According to Christof this is a spurious remains from IHE PCC, where conformance to CCD is requested. But no formal rules can be seen that are not covered by other templates present in Allergy Reaction Observation.
Next this Problem template is also used in the Immunizations and there they also speak about a reaction and there no textual contraint is added to 2.16.840.1.113883.10.20.1.54, so the removal will increase consistency.

Suggestion:

- Remove the textual constaint.

Further explanation:

-

 
 
Busy
Structure Definitions (External repositories)