Your browser does not appear to support JavaScript. You may want to try one of the following:
You may want to try one of the following:
If the above does not work, try reloading the page yourself. Note that you will lose any unsaved changes:
shift
control
Show details
Hide details
This form has to be reloaded. This most likely happened because your session has expired, which might take to the login page. (If you think that you shouldn't see this message and that the problem persists, please contact support.)
- EffectiveTime, Value, interpretationCode, methodCode, targetSiteCode
- change multiplicity to 0..1 and remove the Requirement
-
- In IHE PCC the template 1.3.6.1.4.1.19376.1.5.3.1.4.13 is defined as a generic template "meant to be an abstract representation of many of the observations used in this specification". Here it is specified with specific constraints of code and value for blood group observations. In the epSOS original spec, this template was 1.3.6.1.4.1.19376.1.5.3.1.4.13.6
- Move the constraint from this generic template to a new template "Blood Group Observation" with OID 1.3.6.1.4.1.19376.1.5.3.1.4.13.6, defined as a specialization of 1.3.6.1.4.1.19376.1.5.3.1.4.13
- LOINC code for blood group observation is not in MVC. The code is used in an observation, similar to those in epSOSBloodPressure, but I could not find it in the MVC.
- Should we add it to MVC (Which value set??). And: how is this element handled by the transformer?
Note for the readersThis template version represents the best representation of the original epSOS/EXPAND specifications in ART DECOR. However the original epSOS/EXPAND specifications in Microsoft Word took the original IHE Templates and added constraints in written language. This actually is not best practice in electronic Template Design because the additional constraints are not assigned to the original IHE template but rather than that are text only constraints. In order to make everything computable new Template OIDs need to be assigned to the epSOS Templates in order to cover both, the original IHE Template Design and the additional constraints from epSOS in the text and represent them electronically.
Caveat: for the above mentioned reasons this version cannot be used for (automatic) testing/validation purposes. It shall be used however as basis for refinement (repository)
Note: there is a new version planned that covers all above and makes proper testing/validation possible
- has fixed LOINC code for observation, also has data taype CD for statusCode (while descendants have CS)
- remove code constraints, change statusCode data type
- effectiveTime has cardinality 1..*
-The maximum multiplicity SHALL be lower or equals to the maximum multiplicity from the CDA model [CDATEMP-005]