id: is mandatory in ELGA and other specs; also mentioned in the example but NOT in the template.
Shall be added at least as O to the template, otherwise specifying an id in an instance checked in a closed template environment would lead to an error
-
code: has no Value Set
Shall be the epSOS epSOSBloodPressure value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.21 according to the spec
Only a few concepts in associated value set Obs.code
In the future a value set should contain much more concepts, see e.g. ELGA_Vitalparameterarten 1.2.40.0.34.10.34
text: is in the example but not in the template
Shall be added at least as O to the template, otherwise specifying text in an instance checked in a closed template environment would lead to an error
statusCode: is in the example (fixed to completed) but not in the template
Suggestion:
Shall be added as M fixed completed to the template.
interpretationCode: not used in ELGA
methodCode: has no value set bound to it (like ObservationInterpretation); not used in ELGAtargetSiteCode: has no value set bound to it; not used in ELGA; needs differentiation to methodCode; LOINC would be able to include information about both methodCode and targetSiteCode
How to deal with it now
- The Vital Signs Observation is a specialization of the general Observation template. The general Observation template contains an effectiveTime, so I would expect the Vital Signs Observation template to also contain the effectiveTime element
- Add effectiveTime element to Vital Signs Observation