Help
Login
Busy
Search
International Patient Summary (IPS) - Templates

 
Template locked

OK Not OK
Templates (External repositories)

Warning Ok
Warning
Filter
true50
IPS Pathology Result Observation –
false
History (14)
Date Author Status Type
2018-03-12 11:15:38 Dr. Kai Heitmann Draft version
2017-12-14 10:50:11 Giorgio Cangioli Draft version
2017-12-12 19:15:04 Giorgio Cangioli Draft version
2017-12-10 16:10:31 François Macary Draft version
2017-12-10 16:09:15 François Macary Draft version
2017-12-10 16:05:42 François Macary Draft version
2017-12-10 15:59:40 François Macary Draft version
2017-12-10 15:47:33 François Macary Draft version
2017-12-10 14:34:30 François Macary Draft version
2017-11-09 16:01:24 Giorgio Cangioli Draft version
2017-10-30 18:10:39 Giorgio Cangioli Draft version
2017-10-30 17:47:52 Giorgio Cangioli Draft version
2017-10-18 16:20:37 Giorgio Cangioli Draft version
2017-07-21 08:54:49 Giorgio Cangioli Draft version
false
Issues (3)
false
Request for Information/Education Status = Closed ( hl7ips-issue-44 ): Results organizer (and included obs) code binding
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Low
Current Labels
 
 (CDA) CDA Implementation 
 
 (Vocab) Vocabularies 
Events
Tracking / Status = Closed 2017-05-23 20:01:06 : Tracking by Giorgio Cangioli
 
 CDA 
 
 Vocab 
Description
All the bindings have been added
Tracking / Status = Open 2017-05-10 15:44:27 : Tracking by Giorgio Cangioli
 
 CDA 
 
 Vocab 
Tracking / Status = Open 2017-05-02 11:29:39 : Tracking by Giorgio Cangioli
 
 CDA 
Description
Finding:

Two questions:

  1. should we define a value set for the organzier code or the full LOINC code system is the right one ? The same question applies to any of the included observation (lab, rad,..)
  2. should we harmonize the way the binding is expressed (in this case codesystem fixed to LOINC; or a voc binding with a value set that is the full LOINC code system))  ?
Suggestion:

-

Further explanation:

-

Request for Information/Education Status = Closed ( hl7ips-issue-49 ): results observation: choice for the <value>
Type Request for Information/Education Status Request for Information/Education Status = Closed Priority Normal
Events
Tracking / Status = Closed 2017-06-07 16:30:53 : Tracking by Giorgio Cangioli
Description
included a choice for the observation.values
Tracking / Status = Open 2017-05-02 12:11:41 : Tracking by Giorgio Cangioli
Description
Finding:

Consider to change (or integrate) the constraint "If Observation/value is a physical quantity (xsi:type="PQ"), the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC"
 
into a choice PQ / other data types (if feasible)
define the VS binding explicitly for the PS data type

Suggestion:

-

Further explanation:

-

Change Request Status = Closed ( hl7ips-issue-50 ): VS binding missing for methodCode and targetSiteCode
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (Vocab) Vocabularies 
 
 (STU1Ballot) STU1 Ballot 
Events
Tracking / Status = Closed 2017-10-30 18:44:14 : Tracking by Giorgio Cangioli
 
 Vocab 
 
 STU1Ballot 
Description
Decision taken during the 2017-10-11 call

targetSiteCode: to be removed form Lab and Pathology results. (Giorgio to update the excel file).

methodCode: to be removed results observations / procedure

approachSiteCode: to be removed procedure

targetSiteCode: intensional SCT based value set; preferred value set; not part of the request for free.for-use set… (all descendants of 442083009 |Anatomical or acquired body structure (body structure))

Tracking / Status = Open 2017-09-01 16:18:06 : Tracking by Giorgio Cangioli
 
 Vocab 
 
 STU1Ballot 
Description
reported as ballot comment
Tracking / Status = Open 2017-05-02 12:15:14 : Tracking by Giorgio Cangioli
 
 Vocab 
Description
Finding:

Define and add a value set for the methodCode and  targetSiteCode coded elements

Suggestion:

-

Further explanation:

-

 
 