Issues (3)
false
Change Request Status = Closed ( hl7ips-issue-57 ): Medical Device supply.code: value set binding missing
Type Change Request Status Change Request Status = Closed Priority Normal
Current Labels
 
 (Vocab) Vocabularies 
 
 (TBD) To be discussed 
 
 (STU1Ballot) STU1 Ballot 
Events
Tracking / Status = Closed 2017-11-15 10:09:02 : Tracking by Giorgio Cangioli
 
 Vocab 
 
 TBD 
 
 STU1Ballot 
Description
Call 2017-11-09
The supply code element has not been considered relevant for the purpose of the IPS. It has been omitted 
Tracking / Status = Open 2017-09-01 16:14:24 : Tracking by Giorgio Cangioli
 
 Vocab 
 
 TBD 
 
 STU1Ballot 
Description
reported as ballot comment
Tracking / Status = Open 2017-05-02 15:36:16 : Tracking by Giorgio Cangioli
 
 Vocab 
 
 TBD 
Description
Finding:

No bindings have been defined for this element.
should we omit the element ?
Is this correct ? Should be added some description explaining how it should be used ?

Suggestion:

-

Further explanation:

-

Change Request Status = Feedback needed ( hl7ips-issue-140 ): Add body site to Medical Device (as entryRelationship)
Type Change Request Status Change Request Status = Feedback needed Priority Normal
Events
Tracking / Status = Feedback needed 2020-01-29 12:05:42 : Tracking by Giorgio Cangioli
Description
Added as STU comment
Tracking / Status = Open 2018-03-19 17:49:56 : Tracking by Dr. Kai Heitmann
Description
Finding:

The body site of the implant cannot be specified

Suggestion:

Add a body site as entryRelationship to an implant procedure carrying the body site

Change Request Status = Feedback needed ( hl7ips-issue-141 ): Move the code for binding for Absent or Unknown Devices
Type Change Request Status Change Request Status = Feedback needed Priority Normal
Events
Tracking / Status = Feedback needed 2020-05-27 18:15:56 : Tracking by Giorgio Cangioli
Description
Added as STU comment
Tracking / Status = Open 2020-05-27 17:47:35 : Tracking by Giorgio Cangioli
Description
add as STU comments 
Tracking / Status = Open 2018-03-19 17:57:02 : Tracking by Dr. Kai Heitmann
Description
Finding:

The code for Absent or Unknown Devices is placed now that the participation level code.

Suggestion:

Move the Absent or Unknown Devices code to the Supply.code (that have been dropped earlier but need to be re-introduced here)

Further explanation:

-

 
 
Busy