Item | DT | Card | Conf | Description | Label |
---|
hl7:organizer
| | | | | XeHLizer |
@classCode
| cs | 1 … 1 | F | BATTERY |
@moodCode
| cs | 1 … 1 | F | EVN |
hl7:templateId
| II | 1 … 1 | M | | XeHLizer |
@root
| uid | 1 … 1 | F | 2.16.840.1.113883.2.51.10.70 |
hl7:id
| II | 0 … 1 | R | If present, represents the lab filler order number (ORC-3 and OBR-3 in HL7 v2.5) for this battery | XeHLizer |
hl7:code
| CD (preferred) | 0 … 1 | R | Unique code for the battery in the appropriate vocabulary (e.g. SNOMED CT) | XeHLizer |
| Constraint | The code SHALL be selected out of values in the value-set, which are on level "1-L" or higher (not "0-L" values!) The code SHALL NOT conflict with the Laboratory Study Type Code present at parent "Laboratory Specialty" section.
|
| CONF | |
hl7:statusCode
| CS | 1 … 1 | M | ‘completed’ when all expected results for this battery are in a final state. ‘aborted’ if the battery did not reach the end of testing. Some results MAY be there. | XeHLizer |
| CONF | @code shall be "completed" | or | @code shall be "aborted" |
|
hl7:effectiveTime
| IVL_TS | 0 … 1 | R | Time of results on this battery | XeHLizer |
Choice | 0 … 1 | | Elements to choose from: |
hl7:subject
| | 0 … 1 | | subject in case of a non-human subject attached to the isolate Contains 1.3.6.1.4.1.19376.1.3.3.1.2.1 Non-Human Subject (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | SBJ |
hl7:subject
| | 0 … 1 | | subject in case of a non-human subject attached to the isolate Contains 1.3.6.1.4.1.19376.1.3.3.1.3.1 Human Patient with Non-Human Subject (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | SBJ |
hl7:performer
| | 0 … * | | performer participation. Performer to supersede those recorded at higher level. Contains 1.3.6.1.4.1.19376.1.3.3.1.7 Laboratory Performer (DYNAMIC) | XeHLizer |
hl7:author
| | 0 … * | | author participation used to supersede the authors of higher level. Contains 1.3.6.1.4.1.19376.1.3.10.9.17 Author with Name, Addr, Telecom (DYNAMIC) | XeHLizer |
hl7:participant
| | 0 … 1 | | AUTHEN: The verifier of the battery organizer. In the case where a laboratory report has multiple verifiers. Each verifier is attached to the subset of batteries/observations he or she verified, by the means of a <participant> element.
Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
| XeHLizer |
where [@typeCode='AUTHEN'] | |
@typeCode
| cs | 1 … 1 | F | AUTHEN |
Included | 1 … 1 | M | from 2.16.840.1.113883.2.51.10.74 XeH Lab Results Validator Participant (DYNAMIC) |
hl7:time
| TS | 1 … 1 | M | | XeHLpant |
hl7:participantRole
| | 1 … 1 | M | | XeHLpant |
@classCode
| cs | 0 … 1 | F | ROL |
hl7:id
| II | 1 … * | R | | XeHLpant |
hl7:code
| CE.IPS (preferred) | 0 … 1 | | A code, which identifies the profession/competence/specialty of the author when it is a person.
| XeHLpant |
| CONF | |
hl7:addr
| AD | 0 … * | | | XeHLpant |
hl7:telecom
| TEL | 0 … * | | | XeHLpant |
hl7:playingEntity
| | 0 … 1 | R | | XeHLpant |
hl7:name
| PN | 1 … 1 | R | | XeHLpant |
hl7:participant
| | 0 … 1 | | RESP: The person responsible for the provision of the battery. In the case where this battery is subcontracted to an external laboratory, this external laboratory (with its address and telcom) and the actual performer is represented by a <performer> element, whereas the Director of this subcontractor laboratory is carried by the <participant> element being attached to the same level as the <performer> element. Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
| XeHLizer |
where [@typeCode='RESP'] | |
@typeCode
| cs | 1 … 1 | F | RESP |
hl7:participant
| | 0 … 1 | | DEV: A device or equipment, which was used to produce this battery of results (e.g. an analyzer).
Note: See "other participants" ("AUTHEN", "RESP", "DEV") according to IHE XD-LAB profile
| XeHLizer |
where [@typeCode='DEV'] | |
@typeCode
| cs | 1 … 1 | F | DEV |
Included | 1 … 1 | M | from 2.16.840.1.113883.2.51.10.91 XeH Lab Device Participant (DYNAMIC) |
hl7:participantRole
| | 1 … 1 | M | | XeHLpant |
hl7:id
| II | 0 … * | | The UDI Device Identifier MAY be specified as a second id element.
| XeHLpant |
hl7:playingDevice
| | 1 … 1 | M | | XeHLpant |
hl7:code
| CE.IPS | 0 … 1 | | Coded product type
| XeHLpant |
hl7:manufacturerModelName
| SC | 0 … 1 | | The element manufacturerModelName“ is intended to be used in the same manner as element “modelNumber” specified in the FHIR device resource. It shall carry model information of the device or software provided in element softwareName
| XeHLpant |
hl7:softwareName
| SC | 1 … 1 | M | The element softwareName is the primary element and intended to be used in the same manner as element “deviceName” specified in the FHIR device resource. It should carry the name of the device or software.
Is SHOULD including the manufacturer name.
Note: In case of usage for laboratory related documentation (e.g. Laboratory Result Report), the device structure is also used to record "Laboratory Kits" used for the examination.
| XeHLpant |
hl7:component
| | 0 … * | R | Contains 2.16.840.1.113883.2.51.10.42 XeH Specimen Collection (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |
hl7:component
| | 0 … * | R | Contains 2.16.840.1.113883.2.51.10.56 XeH Laboratory Observation (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |
hl7:component
| | 0 … * | R | Contains 1.3.6.1.4.1.19376.1.3.10.9.2 Multimedia Embedded Content (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |
hl7:component
| | 0 … * | R | Contains 1.3.6.1.4.1.19376.1.5.3.1.4.2 IHE Comment Entry (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |
hl7:component
| | 0 … * | R | Internal reference to an "Order Id" provided in the header of the document (inFullfilmentOf/order/id).
Inherits to elements within the battery.
Note: Usually used in case of multiple orders present
Contains 2.16.840.1.113883.2.51.10.18 XeH Internal Reference (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |
hl7:component
| | 0 … * | R | Internal reference to an "Ordering provider" provided in the header of the document (participant[@typeCode='REF']/associatedEntity/id).
Inherits to elements within the battery.
Note: Usually used in case of multiple orders present
Contains 2.16.840.1.113883.2.51.10.18 XeH Internal Reference (DYNAMIC) | XeHLizer |
@typeCode
| cs | 0 … 1 | F | COMP |