Id2.16.840.1.113883.3.51.60.1.4
ref
bccdapilot-
Effective Date2016‑03‑24 21:39:22
Statusdraft DraftVersion Label
NameCDAauthorDisplay NameBC CDA author
DescriptionTemplate CDA author (prototype, directly derived from POCD_RM000040 MIF)s
ClassificationCDA Header Level Template
Open/ClosedOpen (other than defined elements are allowed)
Used by / Uses
Used by 4 transactions and 7 templates, Uses 2 templates
Used by as NameVersion
2.16.840.1.113883.3.1937.99.61.26.4.9Transactiondraft Medical Imaging Document2016‑10‑08 20:07:38
2.16.840.1.113883.3.1937.99.61.26.4.2Transactiondraft Lab result document2016‑09‑08 18:19:46
2.16.840.1.113883.3.1937.99.61.26.4.7Transactiondraft Base Document2016‑10‑08 19:37:05
2.16.840.1.113883.3.1937.99.61.26.4.5Transactiondraft Create Unstructured Document2016‑10‑04 01:07:56
1.3.6.1.4.1.19376.1.3.3.2.2Containmentdraft BC CDA Laboratory Report Item Section2016‑04‑05 02:22:00
2.16.840.1.113883.3.51.60.2.0Includedraft BC CDA Clinical Document Header2016‑04‑03 18:54:58
2.16.840.1.113883.3.51.60.2.1Includedraft BC CDA ClinicalDocumentLabResult2016‑04‑02 11:52:37
2.16.840.1.113883.3.51.60.2.5.1Includedraft BC CDA ClinicalDocumentMedicalImaging2016‑10‑09 02:16:30
2.16.840.1.113883.3.1818.10.1.7.1Includerejected BC CDA ClinicalDocumentStructuredConsultReport2016‑12‑01 21:39:19
2.16.840.1.113883.3.1937.99.61.26.10.55Containmentdraft Allergy - Intolerance Observation (V2) (2.1)2019‑03‑08 04:36:16
2.16.840.1.113883.10.20.19Includedraft BC CDA ClinicalDocumentUnstrucBody2016‑04‑03 21:54:30
Uses as NameVersion
2.16.840.1.113883.3.51.60.1.5.2Includepending BC CDA Person (2.1)DYNAMIC
2.16.840.1.113883.3.51.60.1.21Includedraft BC CDA DeviceDYNAMIC
RelationshipSpecialization: template 2.16.840.1.113883.10.12.102 CDA author (2005‑09‑07)
ref
ad1bbr-
ItemDTCardConfDescriptionLabel
hl7:author
1 … *MCONFdots0058
@typeCode
cs1 … 1FAUTCONFdots0510
@contextControlCode
cs1 … 1FOPCONFdots0510
hl7:time
TS1 … 1MCONF‑BC0059, CONF‑BC0060
 ConstraintThe author/time.valueSHALL be precise to the day and SHOULD be precise to the minute. If more precise than the day, SHALL include a time zone offset.  This represents the date/time that the clinical document was dictated by the assignedPerson.  In instances where the clinical document is authored by an assignedAuthoringDevice , this date/time represents the time that the document was created by the device. (e.g. ECG auto-interpretation)
hl7:assignedAuthor
1 … 1MCONFdots0061
@classCode
cs1 … 1FASSIGNEDCONFdots0511
hl7:id
II1 … *MCONF‑BC0062, CONF‑BC0063, CONF‑BC0064
 ConstraintIf the author is a Provider, the id elements SHALL conform to section 4.2.1.3.

If the author is a not a Provider, assignedAuthor/id  MAY be a locally assigned identifier
hl7:code
CE0 … 1CONFdots0061
@codeSystem
CONF0 … 1F2.16.840.1.113883.5.111
hl7:addr
AD.CA0 … *CONFdots0061
hl7:telecom
TEL.CA.PHONE0 … *CONFdots0061
Choice0 … 1Elements to choose from:
  • hl7:assignedPerson
  • hl7:assignedAuthoringDevice
hl7:assignedPerson
0 … 1RCONFdots0065
Included from 2.16.840.1.113883.3.51.60.1.5.2 BC CDA Person (DYNAMIC)
@classCode
cs1 … 1FPSNCONFdots0519
@determinerCode
cs1 … 1FINSTANCECONFdots0519
hl7:name
PN.CA1 … *MCONFdots0100
 ConstraintassignedEntity/assignedPerson.name element SHALL conform to the constraints in the common section on names
hl7:assignedAuthoringDevice
0 … 1RCONFdots0065
Included from 2.16.840.1.113883.3.51.60.1.21 BC CDA Device (DYNAMIC)
@classCode
cs1 … 1FDEV
@determinerCode
cs1 … 1FINSTANCE
hl7:code
CE0 … 1BCCDdotsvice
 CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.16040 EntityCode (DYNAMIC)
hl7:manufacturerModelName
SC0 … 1BCCDdotsvice
hl7:softwareName
SC0 … 1BCCDdotsvice