Id2.16.840.1.113883.3.1937.99.61.26.11.3Effective Date2013‑09‑09
Statusfinal FinalVersion Label
NameAcknowledgementDetailCodeDisplay NameAcknowledgementDetailCode
Source Code System
2.16.840.1.113883.5.1100 - Acknowledgement Detail Code - FHIR: http://terminology.hl7.org/CodeSystem/v3-AcknowledgementDetailCode
Level/ TypeCodeDisplay NameCode SystemDescription
0‑L
NS200
unsupported interaction
Acknowledgement Detail CodeThe interaction (or: this version of the interaction) is not supported.
0‑L
NS202
unsupported processing id
Acknowledgement Detail CodeThe Processing ID is not supported.
0‑L
NS203
unsupported version id
Acknowledgement Detail CodeThe Version ID is not supported.
0‑L
NS250
unsupported processing Mode
Acknowledgement Detail CodeThe processing mode is not supported.
0‑L
NS260
unknown sender
Acknowledgement Detail CodeThe Device.id of the sender is unknown.
0‑L
NS261
unrecognized attentionline
Acknowledgement Detail CodeThe receiver requires information in the attentionLine classes for routing purposes.
0‑L
SYN100
required association missing
Acknowledgement Detail CodeRequired association missing in message; or the sequence of the classes is different than required by the standard or one of the conformance profiles identified in the message.
0‑L
SYN101
required attribute missing
Acknowledgement Detail CodeA required attribute is missing in a class.
0‑L
SYN102
data type error
Acknowledgement Detail CodeThe attribute contained data of the wrong data type, e.g. a numeric attribute contained 'FOO'.
0‑L
SYN103
value not found in code system
Acknowledgement Detail CodeAn attribute value was compared against the corresponding code system, and no match was found.
0‑L
SYN104
invalid code system in CNE
Acknowledgement Detail CodeAn attribute value referenced a code system that is not valid for an attribute constrained to CNE.
0‑L
SYN110
number of association repetitions exceeds limit
Acknowledgement Detail CodeThe number of repetitions of a (group of) association(s) exceeds the limits of the standard or of one of the conformance profiles identified in the message.
0‑L
SYN112
number of attribute repetitions exceeds limit
Acknowledgement Detail CodeThe number of repetitions of an attribute exceeds the limits of the standard or of one of the conformance profiles identified in the message.
0‑L
NOSTORE
no storage space for message.
Acknowledgement Detail CodeRejection: The message can't be stored by the receiver due to an unspecified internal application issue. The message was neither processed nor stored by the receiving application.
0‑L
RTEDEST
message routing error, destination unreachable.
Acknowledgement Detail CodeError: The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is unavailable.
0‑L
RTUDEST
error: message routing error, unknown destination.
Acknowledgement Detail CodeThe destination of this message is unknown to the receiving application. The receiving application in the message does not match the application which received the message. The message was neither routed, processed nor stored by the receiving application.
0‑L
RTWDEST
message routing warning, destination unreachable.
Acknowledgement Detail CodeWarning: The destination of this message is known to the receiving application. Messages have been successfully routed to that destination in the past. The link to the destination application or an intermediate application is (temporarily) unavailable. The receiving application will forward the message as soon as the destination can be reached again.
0‑L
PGNE
Placer Group Number Error
Acknowledgement Detail Code'The format of the patient identifier does not match the specification for the indicated patient identifier type.'
0‑L
INVPDOB
Invalid Patient Date of Birth
Acknowledgement Detail CodeThe Patient's date of birth must not be in the future and must not be more than 130 years in the past.
0‑L
INVTRQDT
Invalid Test Request Date
Acknowledgement Detail Code'The test request date must be no more than six months in the past, and no more than thirteen months in the future.'
0‑L
INCTRQST
Incorrect Test Request Status
Acknowledgement Detail Code'The test request status indicated in the message is not valid for the test request.'
0‑L
TRQMIS
Test Request Status/Value Mismatch
Acknowledgement Detail Code'A test result value was provided with a test result status of ‘X’, or a value was not provided and the test result status is not ‘X’.'
0‑L
INVSPECCOLDT
Invalid Specimen Collection Date
Acknowledgement Detail Code'The specimen collection date/time must not be in the future.'
0‑L
PIDMIS
Patient Identifier Mismatch
Acknowledgement Detail Code'None of the patient identifiers in the message match a patient identifier on the existing order.'
0‑L
CLVALRTAV
Clinically Valid Result Available
Acknowledgement Detail Code'A clinically valid result exists in JLIS for the test being ordered. '
0‑L
PNOTAUTH
Practitioner Not Authorized to Order Test
Acknowledgement Detail Codepractitioner type. The indicated ordering
0‑L
LABNOTAUTH
Laboratory Not Authorized to Perform Test
Acknowledgement Detail Code'The test that can be performed vary by laboratory. The indicated performing laboratory is not licensed to perform the indicated test.'
0‑L
PHNNOF
PHN does not exist in the ECR
Acknowledgement Detail CodeThe patient identifier (PHN) provided in the message does not match an identifier existing in the Client Registry.
0‑L
MRNNOF
MRN does not exist in the ECR
Acknowledgement Detail CodeThe patient identifier (MRN) provided in the message does not match an identifier existing in the Client Registry.
0‑L
MRNNOPHN
MRN does not resolve to a PHN in the ECR
Acknowledgement Detail CodeThe patient identifier (MRN) exists in the Client Registry but a PHN has not been assigned.
0‑L
PHNDEP
Personal Health Number has been deprecated.
Acknowledgement Detail CodeThe Patient Healthcare identifier (BC PHN) has been replaced due to a merge. The identifier provided in the message has been superceded.
0‑L
MRNDEP
MRN patient Identifier has been deprecated.
Acknowledgement Detail CodeThe Patient identifier (MRN) has been replaced due to a merge. The identifier provided in the message has been superceded.
0‑L
PIDNOTAUTH
Non-authorized source identifier
Acknowledgement Detail CodeA patient identifier has been provided but the source (assigning authority) is a non-authorized source of registered patient identifiers.
0‑L
PIDDEMMIS
Patient ID - Demographics mismatch
Acknowledgement Detail CodeSupplied patient demographics do not match the demographics recorded in the Client Registry for the primary identiifer supplied in the message.
0‑L
PRNOF
Ordering provider does not exist
Acknowledgement Detail CodeThe Ordering Provider identified in the message does not exist in the Provider Registry
0‑L
PRDEMMIS
Ordering Provider Id - Demographics mismatch.
Acknowledgement Detail CodeSupplied provider demographics do not match the demographics recorded in the Provider Registry for the identifier supplied in the message.
0‑L
RECNOF
iEHR Distribution target is not a user of the system.
Acknowledgement Detail CodeA receiver identified on the iEHR Distribution List is not a user of the system.
0‑L
RECINC
iEHR Distribution target does not have an endpoint designated within the iEHR solution
Acknowledgement Detail CodeA receiver identified on the iEHR Distribution List has no endpoint defined for report distribution.
0‑L
RECINACT
Endpoint for an iEHR Distribution target is not enabled.
Acknowledgement Detail CodeA receiver identified on the iEHR Distribution List has a disabled endpoint.
0‑L
BADMSG
Message Corrupt
Acknowledgement Detail CodeThe PLIS Domain is unable to store the results message in the repository.
0‑L
SFXDATINC
Sending Facility Cross-reference Data incomplete
Acknowledgement Detail Codethe Sending Facility cannot be found in the Sending Facility cross reference data, or if required information is not present for a Sending Facility 
0‑L
LOINCTYPE1
Observation result code is the wrong type
Acknowledgement Detail Codethe Observation code is not a resultable code ('R' or 'B')
0‑L
LOINCTYPE2
Ordered code is the wrong type.
Acknowledgement Detail Codethe Ordered test is not an orderable code (“O” or “B”).
0‑L
SEQXDATNOG
Sequence cross-reference data missing.
Acknowledgement Detail Codea Concatenated Value, or a Battery does not exist in the Sequence Cross-Reference data.
0‑L
SEQXDATINC
Sequence cross-reference data incomplete: Heading ID code or sequence without heading.
Acknowledgement Detail Codea Concatenated Value or a Battery exists in the Sequence Cross-Reference data but a required field is missing (e.g. Heading ID Code, sequence within Heading) - Stored, warning issued, and message sent to Help Desk
0‑L
HXDATNOF
Heading Cross-reference data missing.
Acknowledgement Detail Codea Heading ID Code does not exist in the Heading Cross-Reference data - Stored, warning issued and message sent to Help Desk
0‑L
SHXDATNOF
Sub-Heading cross-reference data missing.
Acknowledgement Detail Codea Sub-Heading ID Code does not exist in the Sub-Heading Cross-Reference data - Stored, warning issued and message sent to Help Desk
0‑L
MICINC
Microbiology culture grid data incomplete. 
Acknowledgement Detail CodeFor the Microbiology Grid Creation, if any of the Concatenated Values are not identified as an Organism or an Antibiotic.

Legenda: Type L=leaf, S=specializable, A=abstract, D=deprecated. NullFlavor OTH (other) suggests text in originalText. HL7 V3: NullFlavors to appear in @nullFlavor attribute instead of @code.
downloadXML JSON CSV SQL SVS