Help
Login
Busy
Search
Pathology controlled vocabulary - Issues

 
Select object
 
false
Results (1 / 1)
Id Issue Status Priority Type Date Assigned To Label
17 Error message during save-operation Open Normal Incident 2023-07-25 09:49:44 Administrator
 
Incident Error message during save-operation
Id pathdv-issue-17
Status Open
Priority Normal
Last Tracking 2023-07-25 09:49:44  by  Prof. Dr. Gunter Haroske
Current Assignee Administrator
    
Concerns
Questionnaire
false
Altes Eingabe-Formular für Klinische Informationen ICCR (pathdv-questionnaire-3)
/
/
Id 2.16.840.1.113883.3.1937.777.18.27.3 Version 2023-06-28T11:56:37
Name Altes Eingabe-Formular für Klinische Informationen ICCR Status Draft
Description
Modell für "intelligentes" Formular (eCRF) Klinischer Angaben (ICCR) für Pathologiesysteme
/
-
/
-
Events
Tracking Open 2023-07-25 09:49:44 : Tracking by Prof. Dr. Gunter Haroske
Description

Error message "Questionnaire contents are not schema compliant: invalid272cvc-maxLength-valid: Value 'Satisfactory for evaluation but limited by lack of pertinent clinical patient information (finding)' with length = '99' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Satisfactory for evaluation but limited by lack of pertinent clinical patient information (finding)' of attribute 'displayName' on element 'code' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Malignant neoplasm of breast (disorder) - Laterality (attribute) = Ipsilateral (qualifier value)' with length = '96' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Malignant neoplasm of breast (disorder) - Laterality (attribute) = Ipsilateral (qualifier value)' of attribute 'displayName' on element 'valueCoding' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Axillary lymphadenopathy (disorder) - After (attribute) = Malignant neoplasm of breast (disorder)' with length = '100' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Axillary lymphadenopathy (disorder) - After (attribute) = Malignant neoplasm of breast (disorder)' of attribute 'displayName' on element 'valueCoding' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Finding of lymph node (finding) - Due to (attribute) |= Biopsy of axillary lymph node (procedure)' with length = '97' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Finding of lymph node (finding) - Due to (attribute) |= Biopsy of axillary lymph node (procedure)' of attribute 'displayName' on element 'valueCoding' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Abnormal histology findings (finding) - Associated morphology (attribute) = Cytologic atypia (morphologic abnormality)' with length = '119' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Abnormal histology findings (finding) - Associated morphology (attribute) = Cytologic atypia (morphologic abnormality)' of attribute 'displayName' on element 'valueCoding' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Procedure with a procedure focus (procedure) : Procedure context (attribute) = Radiology marker (physical object)' with length = '113' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Procedure with a procedure focus (procedure) : Procedure context (attribute) = Radiology marker (physical object)' of attribute 'displayName' on element 'code' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Specimen mammography (procedure) - Has focus (attribute) = Medical reports sent (finding)' with length = '89' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Specimen mammography (procedure) - Has focus (attribute) = Medical reports sent (finding)' of attribute 'displayName' on element 'code' is not valid with respect to its type, 'ShortDescriptiveName'.cvc-maxLength-valid: Value 'Procedure with a procedure focus (procedure) : Procedure context (attribute) = Radiology marker (physical object)' with length = '113' is not facet-valid with respect to maxLength '80' for type 'ShortDescriptiveName'.cvc-attribute.3: The value 'Procedure with a procedure focus (procedure) : Procedure context (attribute) = Radiology marker (physical object)' of attribute 'displayName' on element 'code' is not valid with respect to its type, 'ShortDescriptiveName'."

Assignment 2023-07-25 09:49:43 : Assigned To Administrator by Prof. Dr. Gunter Haroske
    
Labels
Preview Code HTML color Display Name Description