The baseline IHE PCC temnplate seems to request the negationInd attribute set for the observation
verify if this is actualy true and in case add this
-
the data type used is the baseline CD, in epSOS is required that the diaplsyName is provided for several coded element
use a CD.epSOS datat type as done for the CE.epSOS
this templates is used also as specialized template in the allergy section in which is not expected that the code is used
(1) correct the binding
(2) update the template invoked in the history of past illnesses in ordere to have the right value set used
this binding refer three possible value sets.
I suggets that specialized templates would be used in the different context in which this template is actually used. (e..g reaction allergy, problem list)
in this case evaluate if it could be useful to introduce a value set as union of epSOSUnknownInformation and epSOSIllnessesandDisorders
If present the <entryRelationship> element used for the Severity shall have typeCode ‘SUBJ’ and inversionInd ‘true’.
- observation classCode is mandatory
- change cardinality to 1..1
- The current value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.5 does not reflect the most recent version of MVC
- should be updated to contain 4 -digit ICD codes
- In the Template EntryAllergyAndIntolerance [1.3.6.1.4.1.19376.1.5.3.1.4.6] in ART-DECOR, the hl7:id element is not consistent with the inheritance from the template Problem[1.3.6.1.4.1.19376.1.5.3.1.4.5]
- The template EntryAllergyAndIntolerance inherit from the template Problem, the template EntryAllergyAndIntolerance says that hl7:id is 0..* , however the template Problem says that hl7:id is 1..1. This is not permitted to relax constraints.
- Change the EntryAllergyAndIntolerance template and make the id a 1 ... 1 (with a conformance M?)
We noticed that the same OIDs are used in ART-DECOR for defining different templates. This originates from the older implementation guide definitions in the EXPAND period and is a known issue for some time.The majority of conflicts arises from re-using templates from IHE PCC in epSOS, but with additional constraints.I compared the list of templates in epsos: http://art-decor.org/art-decor/decor-template-ids--epsos-with the IHE PCC templates: https://art-decor.ihe-europe.net/art-decor/decor-template-ids--IHE-PCC-I tried to list the templates where the OID is reused in epSOS:
Change the OIDs. To what OIDs has to be discussed and maybe the change has to occur by a change request.
- At this moment we have this constraint on the hl7:code element of the Problem template, while this was not the case in the former EXPAND specifications. The problem arises when we use the 'Allergy And Intolerance' template, which is a specialization of the 'Problem' template. This also has a constraint on the hl7:code element but this time for another Value Set. Since these two constraints conflict, a solution is to relax the constraint on the hl7:code element of the Problem template
- Relax the constraint on hl7:code from the Problem template to be from the value set 1.3.6.1.4.1.12559.11.10.1.3.1.42.23 epSOSCodeProb (DYNAMIC)